Combustion air intakes and pipes must not be obstructed or closed unless special
safety devices are fitted to ensure that the stove can only be operated when the
closing system is open. The cross-section must not be narrowed by a fastening or a
grille. This measure is not necessary with air/exhaust chimneys. If the combustion air
pipe has to be routed out of the building, a shut-off device must be fitted. The position
of the shut-off device must be identifiable from outside. In the case of an external
connection the pipe should be insulated, as condensate may form. Also, when fitting
the pipe it should be ensured that no water or other substances can enter the stove
and that any condensate can drain away outside.
According to the relevant provisions, combustion air lines that bridge firewalls in
buildings with more than two full storeys must be constructed such that
fire and smoke cannot spread to other storeys or fire lobbies. Country-specific and
local fire safety regulations must be observed!
Special instructions for the ambiente a1 and a2
With a combustion air connection with SQC (Spartherm Quick Coupling), the stove is
to be connected as follows.
The stove installation site must be fitted with a supply channel / bore as per the
technical instructions. When mounted directly on the wall, the combustion air and
flue gas connection must be level. The stove is supplied with the mounted SQC and
turned out feet. In this state, the nozzle is in the air and not in contact with the floor.
As such, the stove can be transported with the usual aids (e.g., hand truck).
Chapter 2
Example using ambiente a1:
(Fig.: Transport position with SQC) Fig. 9a
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ambiente at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ambiente in the language / languages: English as an attachment in your email.

The manual is 4.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ambiente

Spartherm Ambiente Usermanual and installation guide - German - 48 pages

Spartherm Ambiente Usermanual and installation guide - Dutch - 48 pages

Spartherm Ambiente Usermanual and installation guide - French - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info