Stove a1/a2/a3/a4 a4 H20a5 a6 a6 a6 H20a6 H20a7 a8
RLA
(non-room
air sealed
operation)
RLU (room
air sealed
operation)
RLA
(non-room
air sealed
operation)
RLU (room
air sealed
operation)
RLA
(non-room
air sealed
operation)
RLA
heat
accumulator
attachment
RLA
convection
air heating
attachment
RLA (non-room
air sealed
operation)
7.9 kW
RLA (non-room
air sealed
operation)
11.0 kW
(export only)
RLA
(non-room
air sealed
operation)
RLA
(non-room
air sealed
operation)
Fuel type Firewood
Nominal heat output (kW) 5.9 5.9 8.0 8.0 7.0 5.9 5.9 7.9 11.0 5.9 5.9
Thermal output range (kW) 4.5-7.7 4.5-7.7 5.6-10.4 5.6-10.4 4.9-9.1 4.5-7.7 4.5-7.7 5.5-10.3 7.7-14.3 4.5-7.7 4.5-7.7
Water heating capacity (kW) - - 5.2 5.2 ---4.9 6.8 - -
Room heating capacity (kW) - - 2.8 2.8 ---3.0 4.2 - -
Wood consumption (kg/h) 1.8 1.8 2.2 2.2 2.2 1.8 1.8 2.3 3.2 1.8 1.8
Efficiency (%) > 80 > 80 > 88 > 88 > 78 >80 >80 >80 85 > 80 > 80
CO content 13% O2 (mg/Nm3)< 1250 < 1250 < 1250 < 1250 < 1250 <1250 <1250 <1250 <1250 < 1250 < 1250
Dust content (mg/Nm3)< 40 < 40 < 40 < 40 < 40 < 40 < 40 < 40 < 40 < 40 < 40
Flue gas temperature at the connecting socket (°C) 350 350 150 1150 1305 317 317 238 249 318 300
Supply pressure (mbar*) 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12
Mass flow of flue gas (g/s) 5.1 5.1 7.6 7.6 6.8 4.3 4.3 7.8 9.6 5.1 5.6
Combustion air requirement (m3/h) 17.5 17.5 26.1 26.1 23.5 17.5 17.5 24.6 31.6 17.8 20.6
Weight according to model (kg) approx.
180-335
approx.
180-335 approx. 230 approx. 230 approx. 225 /
240 / 255
approx.
400-490
approx.
355-445
approx.
340-430
approx.
340-430
approx.
170-205
approx.
200-300
Permitted working overpressure (bar) - - 3.0 3.0 ---3.0 3.0 - -
Maximum permitted
flow temperature (°C) - - 105 105 ---105 105 - -
Max. operating temperature (°C) - - 95 95 ---95 95 - -
Minimum return temperature (°C) - - 60 60 ---60 60 - -
Water-side resistance at 650 l/h (mbar) - - 26 26 ---22 22 - -
Minimum throughput of thermal discharge safety device
(litres) - - 900 900 ---900 900 - -
Water content (litres) - - approx. 29 approx. 29 ---approx. 29 approx. 29 - -
Flow and return connection (IG) - - ¾¨ ¾¨ ---¾¨ ¾¨ - -
Safety heat exchanger
inlet and drain connection (IG) - - ½¨ ½¨ ---½¨ ½¨ - -
Chapter 2
* Depending on the stove,
negative pressures
greater than 20-25 Pa can
influence correct operation.
The pane can become
increasingly contaminated
or noise can be intensified!
1 Due to the low flue gas
temperature of the
ambiente a4 H2O, a suitable
chimney system is required
(not sensitive to moisture)!
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ambiente at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ambiente in the language / languages: English as an attachment in your email.

The manual is 4.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ambiente

Spartherm Ambiente Usermanual and installation guide - German - 48 pages

Spartherm Ambiente Usermanual and installation guide - Dutch - 48 pages

Spartherm Ambiente Usermanual and installation guide - French - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info