Special functions
A simple heat metering function for basic system control can be activated in this menu.
Additional settings regarding the glycol, the percentage of gylcol and the ow rate of
the system are required. A correction value for the heat metering is also possible by
adjusting the “Offset ΔT”.
Since the calculation of the heat metering is based on the temperature of the collec-
tor and storage where measuring takes place, a possible deviation from the ow and
return temperature can be compensated with this value. Example: Displayed collector
temp. 40° C, measured ow temp. 39° C, displayed storage temp. 30° C, measured
return temp. 31° C means a setting of -20% (Displayed ΔT 10K, actual ΔT 8K => -20%
correction value)
Heat metering: Settings range: On/off /default setting: Off
AF type- Settings range: Ethylene/Propylene /default setting: Ethylene
Glycol portion -Settings range: 0-60% /default setting: 40%
Flow rate - Settings range: 10-5000 l/h /default setting: 500 l/h
Offset T - Settings range: -50% to +50% /default settings: 0%
8.6 Heat quantity
Caution
Keep in mind that the system is not changed, adjustments made in this
menu are only used to calculate the heat volume and should be based
on the actual system. Resulting data is only approximate value for func-
tion control!
With some solar systems, especially with vacuum tube collectors, it may
occur that the measurement value acquisition at the collector sensor occurs too slowly
or too inaccurately because the sensor is often not at the hottest location. When the
start help is activated the following sequence is carried out:
If the temperature at the collector sensor increases by the value speci ed under
Increase” within one minute, then the solar pump is switched on for the set “Purg-
ing time” so that the medium to be measured can be moved to the collector sensor. If
this still does not result in a normal switch-on condition, then the start help function is
subject to a 5-minute lockout time.
Start help setting range: on, off/default setting: off
Purging time setting range: 2 ... 30 sec./default setting: 5 sec.
Increase setting range: 1°C....10°C/default setting: 3°C/min
8.7 Start aid function
Caution
This function should only be activated by a specialist if problems arise
with acquisition of measurement values. In particular follow the instruc-
tions from the collector manufacturer.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel TDC 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel TDC 5 in the language / languages: English as an attachment in your email.

The manual is 1.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel TDC 5

Sorel TDC 5 User Manual - German - 56 pages

Sorel TDC 5 User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info