Installation
Low voltagemax.12VAC/DC
Ter minal Connectionfor
S1(2x) Collector
S2(2x) Pool
S3(2x) Flowsensor(optional)
Mains voltage230VAC50-60Hz
Terminal Connectionfor
N MainsneutralconductorN
R1 Filter pump
N MainsneutralconductorN
L Mains phase conductor L
N MainsneutralconductorN
R2 Ballvalve,heatpump
or auxiliary pump
R2 Ball valve
The PE protective conductor must be
connected to the PE metal terminal
block!
max.12V
Caution
Mainsvoltages230VAC
Danger
D. Terminal connection diagram
Low voltage Relays Mains
MainsRelaisKleinspannungen
S3
S3 S2 S2 S1 S1 R2 R1LN N NR2
Flow sensor
Ballvalve,
heat pump
or auxiliary
pump
Pool
Supply
Collector
Filter pump
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel POOL TDC M Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel POOL TDC M Plus in the language / languages: English as an attachment in your email.

The manual is 1.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel POOL TDC M Plus

Sorel POOL TDC M Plus User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info