812334
8
Zoom out
Zoom in
Previous page
1/28
Next page
Installation
Plan des bornes
Low voltages
max. 24 VAC / DC
Haute tension
230 VAC 50 - 60 Hz
Borne: Raccordement pour:
S1 Sonde extérieure
S1 Sonde extérieure (GND)
S2 Sonde ente cc
S2 Sonde ente cc (GND)
S3 Sonde de chambre (RC21)
S3 Terre du sonde (GND-RC21)
V1 Sortie 0-10V; demande de chaleur. Installez
des relais suppmentaires (numéro d'article
77502) si la demande est effectuée via un
contact normalement ouvert.
- GND pour la demande de chaleur
S4 Télécommande (RC21)
+ Borne/
Sortie de tension
Alimentation 24v/DC pour péripriques
externes
Max. charger par des périphériques externes
24V/2W
Borne: Raccordement pour:
N Pompe
R1 Pompe
N Phase principale du conducteur
L Phase principale du conducteur
N Mixeur neutre
R2 Mixeur ouvert
R3| 230v non utili
R3 Vanne mélangeuse fermé
Raccordement conduite PE se fait au bloc en alu
PE
Sur la platine de la régu-
lation
CAN Pour connecter plusieurs gulateurs
entre eux à l'aide d'un ble CAN. Ter-
minez la bus CAN aux deux extrémités en
utilisant des résistances, l'assignation des
connecteurs de bus CAN étant arbitraire!
R3I est finitivement à 230V lorsque le relais est inactif. Un blage incorrect peut endommager les composants connectés.
8
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel MHCC 24V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel MHCC 24V in the language / languages: French as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel MHCC 24V

Sorel MHCC 24V User Manual - English - 28 pages

Sorel MHCC 24V User Manual - German - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info