D - Schéma des bornes pour raccordement électrique
Installation
S6 V1
V2
+S5 S4 S3 S2 S1 -
PELV
R3I
R3 R2 R1 L N
VFS2 VFS1CAN CAN
Danger
Côté secteur 230 VCACôté capteur 12 V max
Attention
Tensions réseau 230VAC 50-60Hz
Bornes: raccordement pour :
L Conducteur Ph. Principale L
N Conducteur Ph. Neutre N
R1 Pompe Principale (opt.)
R2 Relais 2
R3 Relais 3 (Fermé)
R3I Relais 3 (Ouvert)
La mise à la terre de sécurité PE
s’e󰀨ectue au bornier de métal PE !
Basses tensions 12VAC/DC max.
Bornes: raccordement pour :
S1 Circulation (opt.)
S2 Eau sanitaire (Optionnelle, Voir ci-
dessous)
S3 Circuit Principal (opt.)
S4 Mémoire ci-dessus (opt.)
S5 Centre de Conservation (opt.)
V1 0-10V/PWM-Signal Pompe Princi-
pale
V2 0-10V/PWM-Signal (opt.)
S6 Retour Principal (opt.)
- Capteur de Liaison -
VFS1 Sortie d‘Eau Chaude
VFS2 Optionnel
La polarité des sondes est quelconque.
Les connexions des relais changent selon les fonctions additionnelles sélectionnées.
Connexion des capteurs terrestres (1-6) via le capteur du terminal (-)
Le capteur VFS doit être raccordé à la prise sur la carte de circuits.
La capteur 2 / Eau froide: Si aucun capteur n‘est connecté, la température par défaut sera de
10° C. Voir également „6.2 Etalonnage du Capteur“
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel MFWC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel MFWC in the language / languages: French as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel MFWC

Sorel MFWC User Manual - English - 38 pages

Sorel MFWC User Manual - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info