812390
24
Zoom out
Zoom in
Previous page
1/40
Next page
24
Protective functions
To prevent the accumulation of limescale, the circulation pump can continue to rinse
the heat exchanger after a tapping for at least 5 seconds or for longest 30 seconds or
till the VFS sensor drops below Tset.
5.2. - Limescale Protection
If the seizing protection is activated, the controller switches the output in question and
the connected consumer on every day at 12:00 (setting “daily”) or weekly on Sundays
at 12:00 (setting “weekly”) for 5 seconds in order to prevent the pump and/or the valve
from sticking after an extended stationary period.
5.3. - Discharge Protection
If the temperature in the primary circuit is not always guaranteed to su󰀩ce, this function is used.
With this function activated:
When no storage sensor is connected:
If the setpoint temperature is not reached after 60 seconds, the currently measured tempera-
ture -3°C is used as new setpoint temperature. Once the pump in the primary circuit stops, the
setpoint temperature is raised to the set Tset again.
When the storage sensor is connected
If the temperature at the storage sensor is smaller than Tset -5 °C, the target temperature is
lowered to the currently measured storage temperature -5 °C.
In both cases “Circ Tmin” is lowered to the new setpoint temperature - Circ. hysteresis - 5 °C,
where “Circ Tmin is not lower than 0 °C and not higher than the set Circ Tmin.
5.4. - Seizing protection
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel LFWC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel LFWC in the language / languages: English as an attachment in your email.

The manual is 2.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel LFWC

Sorel LFWC User Manual - German - 28 pages

Sorel LFWC User Manual - French - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info