C.3. - Klemmplan
Kleinspannungsseite
max. 12V
Achtung Gefahr
Netzspannungen
230VAC
Netzspannungen 230VAC 50-60Hz An-
schluss im rechten Klemmraum!
Klemme: Anschluss für:
L Netz Außenleiter L
N Netz Neutralleiter N
R1 Ventil (Speicher Mitte)
R2 Zirkulationspumpe
R3 Mischer auf
R4 Mischer zu
R5 Wärmeanforderung
R5I Wärmeanforderung
Der Anschluss der Schutzleiter PE
erfolgt an dem PE Metallklemmblock!
Der Anschluss der Leitung Relais N erfolgt
am Klemmblock Sensor N.
Kleinspannungen max. 12VAC/DC An-
schluss im linken Klemmraum!
Klemme: Anschluss für:
S1 Primär RL
S2 Zirkulation
S3 Speicher Mitte
S4 Primär VL
S5 VFS Warmwasser
(Leitung Gelb)
S6 VFS Durch uss l/min
(Leitung Weiss)
+ VFS +5V DC
(Leitung Braun)
- Brücke Sensor -
(Leitung grün)
Z1 GND
Z2 0-10V Pumpe
Die Polung der PT1000 Fühler ist beliebig.
Der Anschluss der Sensor Masse (S1-S4) und
des VFS erfolgt am Klemmblock Sensor S - .
Das potentialfreie Relais R5 schaltet zur Wärmeanforderung immer wenn der 0-10V
Ausgang eingeschaltet ist.
Über das potentialfreie Relais R5 dürfen nur Netzspannungen von 230VAC und
keinesfalls Kleinspannungen geschaltet werden.
Das Speicherschichtungsventil an R1 wird eingeschaltet und schichtet damit auf die
mittlere Speicherzone wenn S1 > S3.
Achtung
Achtung
Installation
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel FWC 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel FWC 5 in the language / languages: German as an attachment in your email.

The manual is 1.75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel FWC 5

Sorel FWC 5 User Manual - English - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info