Example calculation
lThe installation encompasses 6 collectors with pipe length of 12 meters copper piping with a diameter of 18 mm. The col-
lector content is 2 litres per collector.
lThe collection and connection pipes have a content of 2 litres.
lThe internal heat exchanger has a content of 6.5 litres.
lThe drain set has a content of 40 litres.
Filling quantity of installation:
Collector content: 6 collectors x 2 l 12 l
Content of pipes 12 m x 0,2 l 2,4 l
Content of collection and connection pipes 2 l
Content of heat exchanger 6,5
Content of drain set 40 l
Filling quantity 63 l (rounded up)
Expansion volume vor 63 l filling quantity 51 l - 100 l 6 l
Drain volume of installation
Collector content 12 l
Content of all collection and connection pipes 4,4 l
Expansion volume 6 l
Drain volume of installation 23 l (rounded up)
Installation content 40 l
Drain volume for pressure increase 21 l - 40 l 20 l
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel DrainSet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel DrainSet in the language / languages: English as an attachment in your email.

The manual is 4.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel DrainSet

Sorel DrainSet User Manual - German - 12 pages

Sorel DrainSet User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info