Commissioning of the installation
Filling of the installation
2. Connect the pressure hose of filling station to connection
port (9). The ball valve on connection port (9) is opened.
3. The ball valve (8) is closed.
4. Connect the return hose of filling station to connection port
(7). The ball valve on connection port (7) is opened.
5. Pump the mix of glycol and water into the installation with
the filling station until fluid leaks out at connection port (7).
Shut off filling station and close ball valve on connection
ports (7) and (9).
6. Open ball valve (8) and run installation manually for ca. 15
min - see installation instructions for controller-, in order to
bind entrapped air from the system in the drain set.
7. Afterwards, connect the return hose to the air venting unit
(3). The ball valve on the air venting unit is opened.
8. Connect the pressure hose of the filling station to con-
nection port (7). The ball valve on connection port (7) is
opened. The ball valve (8) is closed.
9. Again, pump mix of glycol and water into the installation
with the filling station until fluid leaks out at the air venting
unit. The installation is now completely filled and vented.
Drain installation
10. In order to maintain the necessary air volume in the install-
ation, a part of the installation has to be drained. In order
to do that, the necessary drain volume has to be determ-
ined see " Drain volume " on page 5 and drained.
11. In order to do that, connect a hose, that leads to a col-
lecting vessel, to the air venting unit (3) . The ball valve on
the air venting unit is opened.
12. Further, connect a hose that also leads to the collecting
vessel, to the filling unit (7). The ball valve (7) is opened.
Ball valves (8) and (9) remain closed.
13. Now, drain the exact volume according to prior determ-
ination from the system!
14. After the drain volume was drained, the ball valves on the
air venting unit (3) and the filling unit (7) are closed.
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel DrainSet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel DrainSet in the language / languages: English as an attachment in your email.

The manual is 4.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel DrainSet

Sorel DrainSet User Manual - German - 12 pages

Sorel DrainSet User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info