699867
82
Zoom out
Zoom in
Previous page
1/97
Next page
SNT EX101/SNT EX104/SNT EP104
Administrating the unit
Transmitting with External Equipment — PTZ control I/F Menu
82
Transmitting with
External Equipment
— PTZ control I/F Menu
When you click in the Administrator
menu, the PTZ control I/F menu is displayed.
Using this menu, you can input data into the system
from the computer via a network and output them to the
external serial interface to control a peripheral device.
You can also input data from a peripheral device via an
external serial interface and output them to the computer
via a network.
Notes
For the SNT-EX104 and SNT-EX154, set the four
video channels to the same setting, except for the
camera ID, which should differ between channels.
setting.
This operation is not available on the SNT-EP104 or
SNT-EP154.
Display sample: SNT-EX101
Interface
Select Coaxitron or Serial.
Serial setting
Standard
Select RS-485 or RS-422.
Note
RS-422 is only available on the SNT-EX101/
SNT-EX101E.
Mode
Select the data transmission/reception method: Network
(TCP) port, or Normal for the camera connection to this
unit. Select Normal when not using TCP.
[Normal]: Operate the camera connected to this unit.
When Normal is selected, you can enter the camera
ID for the connected camera and the protocol and
operation speed.
Camera ID
Configure the Camera ID for the connected camera.
Camera Operation Protocol
[Pelco-D]: Pelco-D protocol.
[AD]: AD protocol.
[Pelco-P]: Peloc-P protocol.
[Bosch]: Bosch protocol.
[Vicon]: Vicon protocol.
[Panasonic]: Panasonic protocol.
[GE]: GE protocol.
[VISCA]: VISCA protocol.
Speed
Configure the default operation speed when
operating the camera connected to this unit. If
operation speed is set outside a protocol’s specified
range, performance will depend on the connected
camera.
Pan
Configure the pan operation speed for the connected
camera.
Tilt
Configure the tilt operation speed for the connected
camera.
Zoom
Configure the zoom operation speed for the
connected camera.
Focus
Configure the focus operation speed for the
connected camera.
[TCP]: Use the TCP port to input and output data
through the external serial interface.
When TCP is selected, you can enter the TCP port
No.
TCP port number
Enter the port number for the data transmission/
reception. Specify a port number (1024 to 65535)
that is not commonly used.
Baud rate
Select a baud rate that corresponds to the peripheral
device of serial interface. You can select one of the
following baud rates:
38400, 19200, 9600, 4800, 2400, 1200 (bps)
Parity bit
Select a parity (none, odd or even) that corresponds to
the peripheral device connected to the serial interface.
PTZ control I/F
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sony SNT-RS1U at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sony SNT-RS1U in the language / languages: English as an attachment in your email.

The manual is 3,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sony SNT-RS1U

Sony SNT-RS1U User Manual - German - 107 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info