680825
75
Zoom out
Zoom in
Previous page
1/96
Next page
75
S10564-00001_Rev-A_EN
13. Operation
Fig. 7
7. After the door CLOSE end position has been reached,
the traffic lights on both sides are switched off.
Both sides: Trafc lights off.
13.4 Obstacle detection
The operator stops and reverses slightly if it encounters
an obstacle. This prevent injury and damage to property.
The door will be partially of completely opened depending
on the setting. The partial reversal is pre-set at the
factory. A full reversal can be set with SOMlink and a
WLAN-enabled device.
INFORMATION
In the automatic closing function the door
opens completely.
INFORMATION
If the photo eye is interrupted, the door
runs on for a long distance.
The following safety devices are installed to detect
obstacles:
Photo eye (object protection)
Safety contact strips (personal protection)
Force cut-off of operator (personal protection)
For more, also note Chapter "14. Maintenance and care".
Force cut-off in door OPEN direction
If the door meets an obstacle, the door stops,
reverses a bit in the door CLOSE direction and
stops.
Operator expects a new command and does not
start automatically.
After receiving a command, the operator moves in
the door OPEN direction.
Force cut-off in door CLOSE direction with automatic
closing function
If the door meets an obstacle, the door stops and
reverses a bit until it reaches the door CLOSE end
position.
The door closes automatically after the open
holding time.
INFORMATION
If the door encounters an obstacle again
in the door CLOSE direction, the operator
stops and reverses completely to the door
OPEN end position. The door stays there.
The automatic closing function is
interrupted. The open holding time and
clearing time do not start again until a
command for door CLOSE.
The door is then automatically closed.
Safety
If the SAFETY safety input is open, the operator stops
the door movement. No more commands are executed.
The potential-neutral NC contact, for example, is suitable
for connecting an emergency stop.
Status LED on the control unit ashes.
Resetting the SAFETY safety input:
1. Reset safety input
(close contact).
2. Execute a command using the button.
Door opens up to door OPEN end position.
Open holding and clearing time run out.
Door closes automatically.
13.5 Power-saving mode
To save energy, the operator control unit switches to
power-saving mode after the factory-specified period.
Connected accessories are deactivated and then
reactivated at the next command from a button or radio.
Connected accessories may include: photo eye, safety
contact strip and external radio receiver.
Because external radio receivers are deactivated in
power-saving mode, they cannot receive commands from
the remote control and send them to the operator.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga in the language / languages: English as an attachment in your email.

The manual is 28,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga

Sommer S 9060 Tiga User Manual - German - 96 pages

Sommer S 9060 Tiga User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info