680828
67
Zoom out
Zoom in
Previous page
1/100
Next page
67
S10557-00001_Rev-A_EN
Safety contact strip for door OPEN
Either an OSE (opto-electronic safety contact strip) or
an 8k2 (electric safety contact strip) can be connected.
During commissioning, the control system automatically
detects which version it is and sets itself to that version.
Connecting 8k2 safety contact strip
+24V
8k2
br
gn
wh
OSE
+24V
8k2
br
gn
wh
OSE
E
OSE
OSE
+24V
8k2
br
gn
8
8
wh
OSE
OSE
O
+24V
br
gn
O
O
O
O
Fig. 8k2 safety contact strip connection for door OPEN
Connect the safety contact strip for door OPEN to the
8k2 terminal block.
The status LED lights up orange when the safety device
has been detected by the control unit.
Terminal block Function
gn 8k2 safety contact strip
wh
The safety contact strip in the door OPEN direction of
motion is triggered.
Status LED ashes orange during the activation.
Operator reverses a bit in the door CLOSE
direction and stops.
Operator expects a new command and does not
start automatically.
After receiving a command, the operator moves to
the door CLOSE end position.
Connecting OSE safety contact strip
+24V
8k2
br
gn
wh
OSE
+24V
8k2
br
gn
wh
OSE
+24V
V
8k2
br
gn
wh
OSE
OSE
O
Fig. OSE safety contact strip connection for door OPEN
Connect the safety contact strip for door OPEN to the
OSE terminal block.
The status LED lights up orange when the safety device
has been detected by the control unit.
Terminal block Function
br = +24 V DC OSE safety contact strip
gn = signal
wh = GND
The safety contact strip in the door OPEN direction of
motion is triggered.
Status LED ashes orange during activation.
Operator reverses a bit in the door CLOSE
direction and stops.
Operator expects a new command and does not
start automatically.
After receiving a command, the operator moves to
the door CLOSE end position.
11. Connections and special functions of the
wall control unit
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga plus in the language / languages: English as an attachment in your email.

The manual is 10,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga plus

Sommer S 9060 Tiga plus User Manual - German - 100 pages

Sommer S 9060 Tiga plus User Manual - Dutch - 100 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info