46900V001_Rev-D_EN
13. Function test/Final test
INFORMATION
After installation of the operator, the
person responsible for the installation
of the operator must complete an EC
Declaration of Conformity for the door
system in accordance with Machinery
Directive 2006/42/EC and apply the CE
mark and a type plate. This documentation
and this installation and operating manual
for the operator must be handed over to
the user.
This also applies if the operator is
retrotted to a manually operated door.
INFORMATION
Reversing: The operator stops when it
meets an obstruction and then moves in
the opposite direction for a short distance
to free the obstruction.
In the automatic closing function the
door opens completely if an obstacle is
detected.
INFORMATION
The operating forces can be modied and
adjusted with SOMlink and a WiFi-enabled
device. For more information ask your
specialist dealer.
After successful testing of the force settings, the obstacle
detection and the functions, the qualified specialist must
issue the EC Declaration of Conformity and attach the
CE mark and type plate to the door system.
The operator must reverse in the door OPEN direction
when it is loaded with a weight of 20 kg. The weight is
fastened in the centre of the bottom edge of the door for
this purpose.
The door must reverse during the door CLOSE
movement if it hits a 50-mm-high obstacle on the ground.
1. Open the door with the operator.
2. Place a 50-mm-high object in the centre of the door.
50 mm
Fig. Example: Obstacle detection on sectional door
3. Close the door with the operator.
If the door hits an obstacle, the operator must
immediately reverse.
The door opens completely at a pulse from the
transmitter.
If the operator does not reverse, a position reset
is required, see Chapter "10.13 Resetting the
control unit". The positions and the forces must
be reprogrammed.
13.2 Handover of door system
The qualified specialist must instruct the user:
on the operation of the operator and its dangers
on the handling of the manual emergency release
on the regular maintenance, testing and care
measures which the user can carry out, see Chapter
"15. Maintenance and care"
on the troubleshooting measures which the user can
carry out, see Chapter "16. Troubleshooting"
The user must be informed about which work must only
be performed by a qualified specialist:
installation of accessories
settings
regular maintenance, testing and care, with the
exception of that described in Chapter
"15. Maintenance and care"
troubleshooting, except that described in Chapter
"16. Troubleshooting"
repairs
The following documents for the door system must be
handed over to the user:
the installation and operating manuals for the
operator and the door
inspection book
EC Declaration of Conformity
handover protocol for the operator
http://som4.me/konform
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 base at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 base in the language / languages: English as an attachment in your email.

The manual is 8,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 base

Sommer S 9060 base Installation Guide - German - 80 pages

Sommer S 9060 base Installation Guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info