46900V001_Rev-D_EN
16.3 Time sequences of operator lighting in normal mode and in case of faults
The flash sequences show information on malfunctions for technicians, end customers and telephone support.
In normal mode
Flash sequences Possible cause Corrective action
Operator lighting blinks as warning light
Programming mode activated
Pre-warning time activated
Reversing movement, soft reversing
and stopped after a soft and
reversing movement
Function for HFL activated
None, for information
In the event of errors
Flash sequences Possible cause Corrective action
Requirement
Operator expects a command
Waiting for a conformation during the
position programming movement of
door CLOSE end position
Conrmationofpositionprogramming
movement
Alarm
A process has triggered a fault
Photocell or safety device not OK
before movement
Check photocell, realign if necessary
If necessary, have components
replacedbyaqualiedspecialist
Interruption of a safety device during
the movement
Remove obstacle
Dead man movement, safety device
not OK
Haveitcheckedbyaqualied
specialist
Motor return from outside (e.g. due
to attempted break-in)
For information
Service
A process has triggered a fault
Service required (service days,
service cycles have been reached)
Have the service performed by a
qualiedspecialist
It may be that after 180 days, the
basic force curve data for the door
operation vary from the actual data
Check weight-balancing and door
mechanism
If necessary, carry out force reset,
see Chapter "10.13 Resetting the
control unit", section "Deleting the
force values"
Motor temperature is too high
(overheating)
Allow motor to cool
Programmingofdifcultpositions
in case of reversing with no visible
cause. The complete distance is
traversed from end position to end
position (dead man by radio, under
direct view only)
For information
Fault
Operator or parts of the operator faulty
Self-test of electronics
Blockage detection (gear breakage,
Hall sensor fault)
Have it checked and, if necessary,
componentsreplacedbyaqualied
specialist
Limit switch does not operate
(e.g. wire break, limit switch fault)
Have cable connections checked
byaqualiedspecialistand,
if necessary, have components
replaced
Counting pulses sent in the wrong
direction (motor cable was incorrectly
connected)
Check wiring, correct if necessary
Run time exceeded Path too long, path restricted to max.
7,500 mm
Error during plausibility test of Memo Haveitcheckedbyaqualied
specialist and, if necessary, have
components replaced
16. Troubleshooting
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9050 base at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9050 base in the language / languages: English as an attachment in your email.

The manual is 8,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9050 base

Sommer S 9050 base Installation Guide - German - 80 pages

Sommer S 9050 base Installation Guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info