Memory slot
Mem
Setting
range
Val
Description of respective
functions
Default setting = Val
marathon tiga SL(X)
003 -
1)
Force taught when opening gate/door (OPEN)
255
3)
004 -
1)
Force taught when closing gate/door (CLOSE)
255
3)
005 -
1)
Runtime when opening gate/door (OPEN)
Value in steps of 0.25 seconds
Example: value shown 40 = 10 seconds
255
3)
006 -
1)
Runtime when closing gate/door (CLOSE)
Value in steps of 0.25 seconds
Example: value shown 40 = 10 seconds
255
3)
011 -
2)
Cycle counter (Z0)
Number of cycles: counter status times 16.536
255
3)
012 -
2)
Cycle counter (Z1):
Number of cycles in total: 256
255
3)
013 -
2)
Cycle counter (Z2) counts from 0 to 255
Total number of cycles:
Z0 × 16.536 + Z1 × 256 + Z2 = number of cycles
255
3)
017 0–255 Length of soft run from gate/door end OPEN
position or gate/door end CLOSE position
Up until acceleration to maximum speed
0 – no soft run, 255 – max. length
0
018 0–8 Length of soft run ramp
High value = long ramp, low value = short ramp
4
019 15–60 Soft run speed when opening 25
020 15–60 Maximum speed when opening 55
4)
Note!
Memory position (020) can only be modified after the control system has been reset
(force values deleted). Such a system reset cannot be completed with the TorMinal software.
1)
Value displayed cannot be changed, and is read and memorised by the control unit when the force
values and travel times are taught.
2)
Value displayed cannot be changed.
3)
Value factory-set. Once the force values and travel time have been taught, the values that are
actually needed are then memorised.
4)
Perform reset, otherwise these values cannot be changed.
Gate/door end
OPEN position
Length soft run
Gate/door end
CLOSE position