Attention!
Always install operator parallel to the guide rails of the door.
Align ceiling bracket (1). It should be located within a range of
(R = 0 ... 600 mm).
Align operator mechanism horizontally to rear centre of door (HM).
Mark position of holes. Drill two holes (Ø 10 x 65 mm).
Wear safety goggles when drilling!
Check thickness of ceiling, particularly in the case of prefabri-
cated garages!
Insert plug (1). Fit two screws (2) with plain washers (3).
Tighten the screws (2).
Align C-rail (4) at correct height. If necessary, change the positions of
the screws (5). Tighten the screws (5).
Mount connecting rod (1):
Insert the long bolt (2) and slide on the securing clip (3).
Attach the door hinge (4) to the connecting rod (1) using the short
bolt (5) and slide on the securing clip (3).
Pull the emergency release rope (N) once. The trolley (1) is released.
Tighten screw (8) at the lintel fixture.
Push the trolley (1) with the connecting rod (2) to the front stop (3).
If necessary, release switch-trigger (4).
Align the door hinge (5) to the centre of the door and mark the 5 drill
holes. Drill 5 holes (Ø 5 mm).
Insert screws that are suitable for securing the hinge to the door.
Wear safety goggles when drilling!
Insert 5 hexagon-head screws (6) and tighten securely.
Release switch-trigger (4) and push right up to trolley (7).
Tighten switch-trigger buffer screw (4) securely.
Release rear switch-trigger buffer (1) and push right back to stop (2).
Open door (3) by hand.
21
21
4
N
1
2
6
max. 30°
4
5
3
20
19
19
2
3
5
4
3
N
1
2
4 8
7
3
6
5
1
N
20
18
17
HM
Trim (e.g. saw off and debur) projecting part of ceiling bracket (4).
Slide the switch trigger (1) to the stop (6) at the trolley (5) until it
engages. Securely tighten screw on switch-trigger (1).
Caution!
After installation, check the drive rail for dirt (e.g. drilling residue)
and clean it, if necessary. Apply a little oil with conductive proper-
ties. See maintenance and care instructions.
Mounting the control unit
Connect to mains voltage according to EN 12453 (all-pole
separating fixture).
Install cable in such a way that it is possible to expand the power
supply in option A (if the cable is at right angles to the C-rail,
install it with a loop).
Position the push button in such a way that the operator can see
the door, while he/she is not inside the operating area of the
door.
Work on the control unit may only be executed if it is de-energised.
Dry any moisture that has penetrated with a blower.
Only qualified electricians may connect the control unit to the mains
supply.
Always install the control unit housing vertically, with the cable channels
downward, without deformation of the housing, so that water cannot
penetrate and so that the lid forms a watertight seal.
Only attach the housing using the intended fixing points, do not drill
through the rear wall of the housing. The housing will leak.
The power cable supplied with the control unit may only be used
for the installation of the drive systems. After completion of the
installation, disconnect the cable and replace it with a duct-laid
cable. It is forbidden to use the supplied power cable for stan-
dard operation of the gate.
22
346
239
6x
361
165
2x M20
6x M16
254
Installation
12
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Marathon Tiga 800 SLX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Marathon Tiga 800 SLX in the language / languages: English as an attachment in your email.

The manual is 3,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Marathon Tiga 800 SLX

Sommer Marathon Tiga 800 SLX User Manual - German - 38 pages

Sommer Marathon Tiga 800 SLX User Manual - Dutch - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info