Functions and connections
21
Procedure:
1. Close door.
2. DIP switch 8 ON activates partial opening.
Always leave DIP switch 8 set to ON, the OFF setting immediately
deletes the set partial opening.
3. Press button 2 (open door from CLOSED end position).
Door opens until button 2 is pressed again or the door reaches
the “door OPEN” end position.
4. Press button 2 once the desired position is reached.
5. Close door with button 2.
Partial opening saved; pressing button 2 opens the door to the
saved position.
NOTE!
Set DIP switch 8 to OFF to delete the partial opening setting.
Partial opening with the hand-held remote
control (2-channel operation)
Programming the 2 buttons of the remote control:
e.g. button 1 on radio channel 1 and button 2 on radio channel 2
Radio channel 1 always has the same function as button 1, terminals 2 + 3
Radio channel 2 always has the same function as button 2, terminals 4 + 5
Procedure as described above.
Automatic closing (DIP 4)
NOTE!
When using the automatic close function, ensure compliance
with standard EN 12453 (e.g. install photo eye 1). An additional
photo eye can be connected to the safety connection 2; this
serves as upper retraction safety.
ATTENTION!
Always install the slip door safeguard on the safety input 2
(terminals 8 + 9). If the slip door safeguard is connected
to the carriage, the drive will not detect the door position.
The door closes automatically after a certain stay-open time, as set with the
potentiometer. The door can only be opened but not closed by a command
from a button or hand-held remote control. While the door is being opened,
it cannot be stopped by a command.
If a command is sent while the door is automatically closing, it will open
completely. A command during the opening time will start the procedure
again from the beginning.
NOTE!
If you use both the partial opening and automatic closing
functions together, rst set partial opening and then
automatic closing.
Set the stay-open time with the potentiometer:
1. The stay-open time can be set as desired for between 1–120 seconds.
Turn the potentiometer in the ON range (1 second increments) for up to
120 seconds.
2. To switch off the stay-open time, turn the potentiometer to the left until
it stops at OFF.
Behavior of drive when safety inputs 1 + 2 are triggered
During door close:
Drive always opens door completely, regardless of the setting of DIP switch 3.
During door open:
Drive behavior depends on the setting of DIP switch 1.
Two-lane control with red traf c light
ATTENTION!
Disconnect internal lighting and do not reconnect.
Both red traf c lights act the same; they blink every time the door is in motion.
Outside red traf c light: terminals 16 + 17, outside of the garage
Inside red traf c light: terminals 18 + 19, inside of the garage
Variant 1: automatic closing function
Automatic closing is activated when the door OPEN end position is
reached. The stay-open time set with the potentiometer starts at this point.
If a command is transmitted during this period, the time period starts again.
Settings:
Set the potentiometer for the desired time (1–120 seconds)
DIP switch 7 + 8 OFF
other DIP switches as desired
Variant 2: automatic closing + photo eye
NOTE!
Install a switch in the photo eye supply line for manual
interruption of automatic close.
However, as described above, the drive closes the door 5 seconds after
crossing the photo eye.
Settings:
Set the potentiometer for the desired time (1–120 seconds)
DIP switch 1, 2, 7 + 8 OFF
DIP switch 4 ON
other DIP switches as desired
21


Need help? Post your question in this forum.

Forumrules
1

Forum

sommer-marathon-550sl

Reset search

  • Salve ho acquistato un garage con l'automatismo Marathon 550 sl .
    Non ho più i telecomandi , sono andati perduti .
    Come devo fare ????
    Stefano Submitted on 26-4-2023 at 16:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Marathon 550SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Marathon 550SL in the language / languages: English as an attachment in your email.

The manual is 4,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Marathon 550SL

Sommer Marathon 550SL User Manual - German - 32 pages

Sommer Marathon 550SL User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info