81
An installation of a Product that does not comply with the manufacturer's specifications
and/or that does not comply with the legal regulations on this matter, will not give rise to
the application of this Warranty. Whenever a Product is installed outside, it must be
protected against meteorological effects, namely rain and winds. In these cases, it may be
necessary to protect the appliance by means of a cabinet, or, properly ventilated protective
box.
Appliances should not be installed in places containing chemicals in their atmosphere,
saline environments or with high humidity contents, as the mixture of these with the air
can produce rapid corrosion in the combustion chamber. In this type of environment it is
especially recommended that the appliance be protected with anticorrosive products for
this purpose, especially between operating seasons. As a suggestion, it is indicated the
application of graphite greases indicated for high temperatures with lubrication function
and anti-corrosion protection.
3.10In the equipment belonging to the pellet family, in addition to the daily and weekly
maintenance that is contained in the instruction manual, it is also mandatory to carry out
the cleaning, inside and its smoke evacuation chimney. These tasks should be carried out
for every 600-800 kg of pellets consumed, in the case of salamanders (air and water)
and compact boilers, and for every 2000-3000 kg of pellets consumed, in the case of
automatic boilers. If these quantities are not consumed, at least systematic preventive
maintenance shall be carried out on an annual basis.
3.11 It is the Buyer's responsibility to ensure that periodic maintenance is carried out, as
indicated in the instruction and handling manuals accompanying the Product. Whenever
requested, it must be proven by the presentation of the technical report of the entity
responsible for it, or, alternatively, by the registration of the same in the instruction
manual in the dedicated section.
3.12 To avoid damage to equipment caused by overpressure, safety elements such as
pressure safety valves and/or thermal discharge valves, if applicable, as well as an
expansion vessel adjusted to the installation must be ensured at the time of installation,
and its correct functioning must also be ensured. It should be noted that: the valves
referenced must have a value equal to or less than the pressure supported by the
equipment; there shall be no shut-off valve between the equipment and the respective
safety valve; a systematic preventive maintenance plan should be provided for to attest