48
s
TROUBLE-SHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTIONS
The appliance
is not working
Appliance is not plugged in Insert the plug into a socket
Atomizer chamber
is not filled with water
No water in reservoir (indicator
light shows it is empty)
Fill the water reservoir
Decalcification cartidge used up Change the decalcification
cartidge
Mist output is too low Water temperature too low Set the atomization level to the
maximum. After about 10 mins
the appliance will be working
perfectly again
Calcification on the membrane Clean the membrane
White precipitate
throughout the appliance
Decalcification cartridge used up Change the decalcification
cartridge
s
TECHNICAL INFORMATION
Model-No. DF-HU23010, Type 711
Product description SOLIS Vapo-Flûte Ultrasonic-Humidifier
Voltage / Frequency 220–240 V~ / 50 Hz
Power 35 Watt
Noise level 40 dBa
Surrounding-temperature 10 °C–40 °C
Suitable room size 45 m
2
/ 108 m
3
Weight 2,5–2,7 kg
Dimensions ca. 57–110 x 22,5 cm (H x Ø)
Max. Water-capacity of the reservoir 4,5 l
Atomization volumes:
1. level: 40 %, 160 ml/h 2. level: 50 %, 200 ml/h
3. level: 60 %, 240 ml/h 4. level: 70 %, 280 ml/h
5. level: 80 %, 320 ml/h 6. level: 90 %, 360 ml/h
7. level: 95 %, 380 ml/h 8. level: 100 %, 400 ml/h