14
TECHNISCHE DATEN
Artikel-Nr.
SN
68108 (Modell: TMB-1491-D)
Energiezufuhr Batteriebetrieb: 4 Alkalibatterien AAA 6 V DC
Betrieb mit Netzstromadapter 6 V
1 A
(Bitte nur den empfohlenen Netzstromadapter verwenden.)
Anzeigemodus LCD-Display (40 x 60 mm)
Messmodus Oszillographischer Prüfmodus
Messbereich Soll-Manschettendruck: 0 mmHg – 300 mmHg (0 kPa – 40 kPa)
Messdruck
SYS: 60 mmHg – 230 mmHg (8,0 kPa – 30,7 kPa)
DIA: 40 mmHg – 130 mmHg (5,3 kPa – 17.,3k Pa)
Pulswert: (40 – 199) Schläge pro Minute
Genauigkeit Druck: 5 °C – 40 °C innerhalb von ±3 mmHg (0,4 kPa) Pulswert bei:
±5 %
Normale Betriebs-
bedingungen
Temperaturbereich: 5 °C bis 40 °C
Relative Feuchtigkeit: ≤85 %
Luftdruckbereich: 86 kPa bis 106 kPa
Lager- und Trans-
portbedingungen
Temperatur: -20 °C bis 60 °C
Relative Feuchtigkeit: 10 % bis 93 %
Luftdruckbereich: 50 kPa bis 106 kPa
Messumfang am
Oberarm
22 cm – 42 cm
Gewicht ca. .175 g (ohne Batterien und Manschette)
Außenmaße ca. 110 mm ×110 mm × 41 mm
Zusatzteile 4 Alkalibatterien AAA
Betriebsart Durchgängiger Betrieb
Schutzart Anwendungsteil des Typs BF
Schutz vor Wasser-
eintritt
IP21 bedeutet, dass das Blutdruckmessgerät vor festen Fremdkörpern
einer Größe von 12,5 mm und mehr sowie gegen senkrecht fallende
Wassertropfen geschützt ist.
Software-Version A01
WARNUNG:
Änderungen am Gerät sind nicht zulässig.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Soehnle 68108 - Systo Monitor 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Soehnle 68108 - Systo Monitor 200 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info