4
A. Operating elements
1. Minus ( )
2. Confirm (
)
3. Plus (
)
B. Preparation
1. Insert batteries.
Note:
Place the body analysis scale immediately on
a solid and even surface (as long as „0,0“ is
still displayed) and wait until the scale turns
off automatically.
Only then begin with data input. Note, it
might occur that the initial scale weight is
being added erroneously to the personal
weight process.
The same may happen during regular operati-
on, if scale is held in the hand prior to the
weight process.
2. Place scale level on a solid and even surface
(not carpet). This applies for all measure-
ments.
3. Cleaning and care: use only a lightly damp
cloth for cleaning. Do not use solvents or
abrasives. Never submerge scale in water.
4. A country-specific option, to switch from kg/
cm to lb/in or st/in, is available on the back of
the scale by pushing button.
Attention! Slipping hazard
in case of wet surface.
C. Data input
1. Push button.
2. Use
/ buttons to select memory slot. Use
to confirm.
Þ
P
3. Then use
/ buttons enter body height and
confirm.
Þ
H
4. Enter the age and confirm.
Þ
A
5. Select gender and confirm (Press
button
3 sec.).
Þ
S
6. Place the body analysis scale immediately on
the floor, wait until screen displays „0,0“ and
then step on the scale with bare feet.
The initial measurement is indispensable and
serves to store data for later automatic recog-
nition. If user does not step on the scale, data
cannot be saved and must be entered again.
The first body analysis is performed after a
person steps on the scale.
This scale is equipped with a timeout mode.
It will automatically switch off after approx.
40 seconds, if no buttons are pressed.
Data must be entered again after battery
change.
D. Body analysis
Place scale on solid and even surface. Wait
until scale switches off automatically.
1. Step barefoot onto scale. Stand still.
2. Determined body weight is displayed.
The automatic user recognition follows.
3. If the determined values cannot be clearly
allocated to one user, the possible memory
slots will be displayed.
If the determined weight can be allocated to
more than 2 users, other possible memory
slots will be displayed after 3 seconds.
Use the
/ keys ( = left, = right) to con-
firm the memory slot displayed there.
The scale measures body values (body fat,
body water) and BMI (Body Mass Index).
The 9-segment status bar shows the respecti-
ve deviation from the normal value (see over-
leaf).
The scale turns off auto matically.
Classification of body weight according to BMI
(Source: World Health Organisation, 2016)
BMI (kg/m²) classification
< 18.5 Underweight
18.5 - 24.9 Normal weight
25.0 - 29.9 Pre-Obesity
30.0 - 34.9 Obesity level I
35.0 - 39.9 Obesity level II
> 40.0 Obesity level III
EN
63868-BA-PWD-Shape-Sense-Profi-100-14028-A-Content-04-11-2016.indd 4 04.11.2016 17:21:50
6


Need help? Post your question in this forum.

Forumrules
1

Forum

soehnle-63868---shape-sense-profi-100

Reset search

  • I have a pacemaker and I was wondering if the Soehnle 63868 - Shape Sense Profi 100 weighing scales bmi function can be turned off in order to make the scales safe with pacemaker use? Submitted on 26-5-2023 at 07:31

    Reply Report abuse
  • We have the new scaes model 563868. There is no manual and we do not know how to set up the actual start up to use these scales. Submitted on 8-9-2022 at 10:03

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Soehnle 63868 - Shape Sense Profi 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Soehnle 63868 - Shape Sense Profi 100 in the language / languages: All languages as an attachment in your email.

The manual is 5,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info