Admin and Installation Guide M900 Description of Settings
Setting Description
System combination (number
of base stations/repeaters
per base station)
Three settings are available.
Note: The conguration must be set at the time the multicell system is
congurated. It cannot be modied:
50/3: 50 base stations and 3 repeaters
127/1: 127 base stations and 1 repeater
254/0: 254 base stations and 0 repeater
Base Station Group (Fig. 2)
ID Base station identity in the chained network. Automatically assigned
consecutively when new base stations are added to the chain. With checkbox
for selection for removal from chain.
Permitted output: Positive integers.
RPN The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the
installer. The allocated RPN within the SME must be geographically unique.
Permitted output: 0 to 255 (DEC) or 0x00 to 0xFF (HEX)
Version Current rmware version on base station.
Permitted output: Positive integers with dot (e.g, 355.21).
MAC address The media access control (MAC) address is a unique identier assigned by the
manufacturer. Printed on device's label and on Home page of web interface.
IP address The Internet Protocol address assigned by the network the base station is
located in.
IP status Current base station status in the SME network.
This unit: Indicates that you are looking at this base station's web interface.
Connected: The base station is online in the network.
Connection lost: The connection to the base station has been lost.
DECT sync source The drop-down menu contains the RPNs of each of the currently connected
base stations followed (in parentheses) by the strength of the respective radio
signal (RSSI) in dBm, as received by the base station whose web interface you
are currently accessing. The maximum number of multicell chain levels is 24.
When the DECT system setting Auto congure DECT sync source tree is
set to "enabled", the sync source tree will be generated automatically.
When the setting is "disabled", the sync source tree must be congured
manually by selecting each base station's sync source from the drop-
down menu.
The visible option shows which sync source each of the base stations in the
DECT chain is currently using. If you select a dierent option, the chain must
be rebooted. Options:
Select as primary: This option is visible when the base station is selected
as the primary. Select from the drop-down menu of a secondary base
station to make that base station the primary.
Primar y:RPNxx (-xxdBm): This option is visible when the base station is
a secondary level base station whose sync source is the primary.
Example: Primary:RPN00 (-72dBm)
Levelx: RPNxx (-xxdBm): This option is visible when the base station is a
secondary level base station whose sync source is another secondary
level base station.
Example: Level1:RPN04 (-68dBm)
(any) R PN: Indicates a base station that is not synchronized to any other base
station.
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M900 in the language / languages: English as an attachment in your email.

The manual is 4.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M900

Snom M900 User Manual - English - 44 pages

Snom M900 User Manual - German - 79 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info