Admin and Installation Guide M900 Description of Settings
Setting Description
Outbound proxy Session border controller DNS or IP address. Alternatively SIP server
outbound proxy address. Set the outbound proxy to the address and port
of the private NAT gateway so that SIP messages are sent via this gateway.
Format: addr:port
Default value: Blank
Conference server For Broadsoft conference server only: If the IP address of the server is set
in this text eld, pressing the handset's conference function key during a call
will establish a connection to the conference server. If the eld is empty, the
system's 3-party local conference is used.
Call log server Broadsoft call log feature. If the IP address of the server is set in this
text eld, pressing the handset's call log/call history key during a call will
establish a connection to the call log server.
Reregistration time (s) The “expires” value signaled in SIP REGISTER requests. This value indicates
how long the current SIP registration is valid, and hence it species the
maximum time between SIP registrations for the SIP account.
Permitted value(s): Maximum 65636 seconds. A value below 60 seconds is
not recommended.
SIP Session Timers RFC 4028. A “keep-alive” mechanism for calls. The session timer value
species the maximum time between “keep-alive” or more correctly session
refresh signals. If no session refresh is received when the timer expires, the
call will be terminated.
Default: Enabled.
Session timer value (s) Default value: 1800 seconds.
Permitted values: Minimum 90 sec, maximum 65636 sec.
If the setting is disabled, session timers will not be used.
Use SIP as XSI authentication TBA
SIP Transport Default: UDP. Other options: TCP, TLS 1.0
Signal TCP Source Port When SIP Transport is set to TCP or TLS, respectively, a TCP or TLS connection
will be established for each SIP extension. The source port of the connection
will be chosen by the TCP stack, and the local SIP port parameter specied
in the SIP/RTP settings will not be used. The “Signal TCP Source Port”
parameter species whether the used source port shall be signaled explicitly
in the SIP messages.
Default: Enabled.
Use one TCP connection per
SIP extension
When using TCP or TLS as SIP transport, choose whether the base station is
to establish one TCL or TLS connection for each SIP extension or one TCL or
TCS connection that all SIP extensions will use. Note: If TLS is used and the
SIP server requires client authentication (i.e., requests a client certicate),
this setting must be disabled.
Settings: Disabled (one TCL or TLS connection for all SIP extensions);
Enabled (one TCL or TLS connection for each SIP extension)
Default: Disabled
RTP from own base station If disabled, the RTP stream will be sent from the base station where the
handset is located. I enabled, the RTP stream will always be sent from the
base station where the handset is registered.
Default: Enabled
Keepalive Default: Enabled. When enabled, a new keepalive message will be sent out to
the Registrar/Proxy port after 30 seconds in order to have the port stay open
and the phone remain reachable.
Show extension on handset
idle screen
Default: Enabled. When enabled, the extension number is displayed on the
idle screen of the handset.
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M900 in the language / languages: English as an attachment in your email.

The manual is 4.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M900

Snom M900 User Manual - English - 44 pages

Snom M900 User Manual - German - 79 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info