4. INSTALLATION
12
IT
EN
4.1 Dimensions of the appliance
The overall dimensions are illustrated in FIG. 5 - PG. 21 with the cavity diagrams.
The overall dimensions include the trivet (pan support), control knobs, handles and gas connection.
4.2 Fitting cavity
WARNING
WARNING
The appliance must fitted at an appropriate and safe distance from flammable
materials.
WARNING
WARNING
For the CU..., FO... and VN555 models, the cavity that the appliance is built into
must be completely sealed off. It is important that the inside panels of the cavity are
completely sealed and do not communicate with adjoining cavities or the outside.
The openings in the cavity that allow access to the gas and electric connections
should be sealed with rubber or foam.
The gas connection (1/4 BSPT female) is located at the rear for models CU..., FO... and for model VN555,
whereas it is on the bottom for models PI... and MO...
The electric connection is located at the rear for models CU..., FO... and for model VN555, whereas it is on
the bottom for models PI... and MO... (consult chapter 4.4 Electric connection to see whether the appliance
needs this connection).
Minimum allowable distances from walls (FIG. 4 - PG. 20)
200 mm From the external edge of the burner head nearest to a side and / or back wall.
600 mm Between the top part of the burners and cabinets and / or shelves fitted above the hotplate.
100 mm From the sides of the appliance and vertical walls.
170 mm From the top side to the cabinets and / or shelves fitted above the appliance.
Dimensions of fitting cavity
Cut out a hole in the cabinet as illustrated in FIG. 5 - PG. 21 size will depend on appliance model.
The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit.
The cabinet aperture must be perfectly squared and aligned. If there are apertures for cabinet ventilation,
prevent flammable materials from entering these.
4.3 Gas connection
WARNING
WARNING
This appliance shall be installed only by authorised persons and in accordance with
the manufacturer’s installation instructions, local gas fitting regulations, municipal
building codes, electrical wiring regulations, AS 5601-2004 - Gas Installations and any
other statutory regulations.
WARNING
WARNING
This appliance is not connected to a flue terminal which discharges the product of
combustion to the outside. Any enclosed space in which the appliance is installed
must therefore be provided with permanent ventilation in accordance with relevant
federal and state regulations in force, and the requirements of gas installations with
particular attention being paid to the matter of room ventilation.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smev CU403PE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smev CU403PE in the language / languages: English as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info