660414
20
Zoom out
Zoom in
Previous page
1/22
Next page
Instructions for the installer
22
9.4 Adjustment for natural gas G20 - G20/G25
The cooker hob is preset for natural gas G20 (2H) - G20/G25 (2E+)
at a pressure of 20 mbar - 20/25 mbar . To reset the appliance
for operation with this type of gas, carry out the same steps as described in “9.2
Adjustment for LPG”, but select the nozzles and adjust the primary air for natural
gas as indicated in the table below and in "9.5 Primary air adjustment”. After the
adjustments have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20/G25 20/25 mbar
G20 20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary (1) 1.05 73 380
Semi-rapid (2) 1.65 92 380
Medium rapid (3) 2.55 115 650
Large Rapid (4) 3.1 126 750
Ultra-rapid (5) 3.3 130 1200
Double crown
Internal (6) 1.05 73 380
External (6) 3.9 140 1200
Fish burner 2.0 100 750
9.5 Primary air adjustment
Refers to distance “X” in mm.
BURNER
G30/G31
28/37 mbar
G20/G25
20/25 mbar
G20 20 mbar
G25
20 mbar
G30/G31
50 mbar
Auxiliary (1) 1.0 1.5 1.5 0.5
Semi-rapid (2) 1.5 1.5 1.5 1.0
Medium rapid (3) 1.5 1.0 1.0 1.5
Large Rapid (4) 10.0 2.5 1.5 1.5
Ultra-rapid (5) 2.5 2.0 1.0 1.5
Double crown
Internal (6) 6.0 3.0 2.0 3.0
External (6) 10.0 3.0 1.5 10.0
Fish burner 2.5 2.0 2.0 1.5
To identify the burners on your hob, refer to the drawings in “9.7 Arrangement of the burners on the
cooking hob”.
BE
BE
BE
BE
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg SR775RAD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg SR775RAD in the language / languages: English as an attachment in your email.

The manual is 1,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg SR775RAD

Smeg SR775RAD User Manual - German - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info