Instructions for the Installer
24
4. Gas connection
If the appliance is installed above an oven, the gas hose must be passed around the
back of the oven to prevent overheating.
The connection to the gas mains may be made using a copper pipe or a continuous-wall
steel hose in accordance with the relevant regulations. To simplify connection, the
horizontal position of the fitting A on the back of the appliance is adjustable. Undo the
hexagonal nut B, turn the fitting A into the required position and re-tighten the
hexagonal nut B (it has a rubber gasket to ensure it provides an effective seal). When
installation is complete, check for any leaks with a soapy solution, never with a naked
light. The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. For
use with other types of gas, see section "
5 Adapting to different types of gas". The gas
intake connection has an external ½” gas thread (ISO 228-1).
Connection with copper pipe: The connection to the
gas supply mains must be made so that no stresses or
strains of any kind are applied to the appliance. The
connection can be made using the adapter unit D with
two conical elements, always fitting the gasket C
supplied.
Connection with steel hose: use only continuous-wall
stainless steel hoses compliant with the relevant
regulations, and always fit the gasket C supplied
between the fitting A and the hose E.
When connecting with a hose, ensure that the total length of the pipeline is not more
than 2 metres; also ensure that the hoses do not touch moving parts and are not
crushed.
4.1 Bottled gas connection
Use a pressure regulator and make the connection to the gas cylinder in accordance
with the relevant regulations. Make sure that the gas supply pressure is as stated in
the table in point "5.2 Adjusting for bottled gas".
4.2 Room ventilation
The appliance may only be installed in a permanently ventilated room as specified by
the relevant regulations. The air flow into the room where the appliance is installed
must be sufficient for proper gas combustion and room ventilation. The air intakes,
protected by gratings, must be of suitable size (see relevant regulations) and located
so that they cannot be even partially obstructed.
The kitchen must be kept properly ventilated to disperse the heat and humidity
produced by cooking processes: in particular, a window should be opened or the
speed of any fans increased after prolonged use.
4.3 Combustion gas discharge
Combustion gases must be discharged by means of hoods connected to a flue with
reliable natural draught, or a fan extraction system. An effective extraction system
requires careful design by an authorised specialist, and must comply with the
regulation distances and positions. After installation, the engineer must issue a
certificate of compliance.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg px 140 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg px 140 in the language / languages: English as an attachment in your email.

The manual is 2,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg px 140

Smeg px 140 User Manual - German - 16 pages

Smeg px 140 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info