Installation
43
EN
Carefully screw the connector 3 to the gas
connector 1 of the appliance, placing the
seal 2 between them.
Connection with a flexible steel hose with
conical fitting
Make the connection to the gas mains
using a continuous wall flexible steel hose
whose specifications comply with the
applicable standard.
Carefully screw the hose connector 3 to the
appliance’s gas connector 1 (½” thread
ISO 228-1), placing the supplied seal 2
between them. Apply insulating material to
the thread of connector 3, then tighten the
flexible steel hose 4 to the connector 3.
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder following
the guidelines set out in the regulations in
force.
The supply pressure must comply with the
values indicated in the table in “Gas types
and Countries”.
Room ventilation
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow needed for the
regular combustion of gas and the
necessary air change in the room itself. The
air vents, protected by grilles, must be the
right size to comply with current regulations
and positioned so that no part of them is
obstructed, not even partially.
The room must be kept adequately
ventilated in order to eliminate the heat and
humidity produced by cooking: in
particular, after prolonged use, you are
recommended to open a window or to
increase the speed of any fans.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg PV175CND at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg PV175CND in the language / languages: English as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg PV175CND

Smeg PV175CND User Manual - German - 26 pages

Smeg PV175CND User Manual - Dutch - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info