Instructions for the installer
26
5.2 Regulation for LPG
Loosen screw C and push air regulator D to the
bottom.
With a 7 mm wrench, remove nozzle E and
replace it with the proper one (follow the
instructions on the reference tables for the type of
gas to be used). The torque wrench setting of the
nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator D until
reaching distance “X” shown in the table in
paragraph “5.4 Regulation of primary air ”.
Lock regulator D by tightening screw C.
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 48 30(**) 33 (*) 450 73 71
Semi rapid 1.65 62 32(**) 35 (*) 500 120 118
Medium rapid 2.3 75 38(**) 43 (*) 700 167 164
Large rapid 3.0 82 42(**) 45 (*) 800 218 214
UR
A
3.6
76
48 (**) 52 (*) 1000 261 257
B 48
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown inpoint “5.6
Regulation of minimum for natural gas”.
CAUTION: for references A and B on
the lh UR and rh UR burners, see
drawings at side.
5.3 Regulation for natural gas
The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To
allow the unit to work with this type of gas, perform the same operations described in
paragraph “5.2 Regulation for LPG ”, but choose the nozzles and regulate the primary
air for natural gas, as shown in the following table and in paragraph “5.4 Regulation of
primary air ”.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 73 400
Semi rapid 1.65 92 500
Medium rapid 2.3 110 700
Large rapid 3.0 126 800
UR
A
3.6
115
1000
B 73
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg PNL 106 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg PNL 106 in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg PNL 106

Smeg PNL 106 User Manual - German - 15 pages

Smeg PNL 106 User Manual - Dutch - 15 pages

Smeg PNL 106 User Manual - Dutch - 15 pages

Smeg PNL 106 User Manual - French - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info