72838
11
Zoom out
Zoom in
Previous page
1/18
Next page
Instructions for the installer
31
5.3 Regulation for natural gas
The hob has been inspected for G25 (2L 3B/P) at a pressure of 2 mbar.
To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "
5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G25 25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary (1) 1.05 76 380
Semi-rapid (2) 1.65 98 380
Rapid (3) 2.7 123 650
Rapid (4) 3.1 130 750
Ultra rapid (5) 3.9 150 1400
5.4 Regulation of primary air
Referred to distance “X” in mm.
BURNER G25
25 mbar
G30/G31
28/37 mbar
Auxiliary (1)
1.5
2.0
Semi-rapid (2)
1.0
1.5
Rapid (3)
1.0
5.0
Rapid (4)
1.5
10.0
Ultra rapid (5)
1.5
4.0
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg GKC 641 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg GKC 641 3 in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg GKC 641 3

Smeg GKC 641 3 User Manual - German - 20 pages

Smeg GKC 641 3 User Manual - Dutch - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info