Instructions for the Installer
38
14.2 Ventilation requirements
The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.
1 All rooms require an opening window or equivalent, and some rooms will require a permanent vent as
well.
2 For room volumes up to 5 m
3
an air vent of 100 cm
2
is required.
3 If the room has a door that opens directly to the outside, and the room exceeds 1 m
3
no air vent is
required.
4 For room volumes between 5 m
3
and 10 m
3
an air vent of 50 cm
2
is required.
5 If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be
consulted to determine the air vent requirements.
6 This appliance must not be installed in a bed sitting room of less than 20 m
3
or in a bathroom or
shower room.
Windows and permanent vents should therefore not be blocked or removed without first consulting a
Corgi gas installer. Failure to install appliances correctly is dangerous and could lead to
prosecution.
14.3 Connecting to natural and LPG gas (Please see connection diagram)
Make the connection to the appliance using flexible bayonet style hose in accordance
to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal
thread. Please use seal C between the flexible connection L and the appliance
supply tube B. When making the connection, make sure that no stress of any kind is
applied to the cooker and that the hose does not touch any sharp edges. If
connecting to LPG the bayonet hose must have red bands on it.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg C 9 GMN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg C 9 GMN in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg C 9 GMN

Smeg C 9 GMN User Manual - English - 20 pages

Smeg C 9 GMN User Manual - German - 22 pages

Smeg C 9 GMN User Manual - German - 20 pages

Smeg C 9 GMN User Manual - Dutch - 22 pages

Smeg C 9 GMN User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info