658164
28
Zoom out
Zoom in
Previous page
1/33
Next page
Air Dryer (IDF1E-10
IDF15E-10/20) 5 Troubleshooting
5 - 1
Troubleshooting
Should any problem occur, inspect the following table, and if the problem cannot be solved, shut off the power supply and
then contact one of our sales offices for further instructions.
Problem Probable Causes Remedy
Air dryer does not
operate and running
lamp does not light on,
even switch is ON.
Power cord or plug is in loosening state
or completely pulling out.
Perform proper connection on the power cord and plug.
Circuit breaker is OFF.
Confirm whether the proper capacity of the circuit
breaker is used.
It is not possible to restart the air dryer within 3
minutes after shutdown. Wait for 3 minutes before
restarting.
Resume the operation after resetting the circuit
breaker to ON. If the circuit breaker still trips to OFF,
failure of electrical insulation may have occurred.
Remove the power supply and contact one of our
agents for further instructions.
Running lamp
extinguishes and
compressor stops
during operation but
resumes normal
operation
illuminating the
lamp after a
period of time.
Installation place is poorly
ventilated. Ambient temperature
is too high.
Improve the ventilation system to lower the ambient
temperature.
The ventilation grilles are
obstructed by wall or clogged
with dust.
Install the air dryer more than 600mm away from the
wall.
Clean the ventilation grilles once a month.
Temperature of the compressed
air is too high.
Improve the ventilation system around air
compressor or make ambient temperature around air
compressor low to lower the temperature of
discharge from compressor.
Reduce the temperature of the compressed air by
installing an additional after-cooler after air dryer.
Supply voltage is not in the
following range:
100VAC: 90V ~ 110V/90V ~
121V (50/60Hz)
200VAC: 180V ~ 220V/180V ~
242V (50/60Hz)
Set the voltage to a proper value by installing a
transformer or review the electrical wiring.
Evaporation
thermometer indicates
higher than green zone.
Installation place is poorly
ventilated. Ambient temperature
is too high.
Improve the ventilation system to lower the ambient
temperature.
The ventilation grilles are
obstructed by wall or clogged
with dust.
Install the air dryer more than 600mm away from the
wall.
Clean the ventilation grilles once a month.
Temperature of the compressed
air is too high.
Improve the ventilation system around air
compressor or make ambient temperature around air
compressor low to lower the temperature of
discharge from compressor.
Reduce the temperature of the compressed air by
installing an additional after-cooler after air dryer.
Moisture occurs
downstream of the
compressed air
lines.
Bypass valve of air dryer is not
fully closed.
Close the valve completely.
Drain is not discharged from auto
drain properly.
Check if the drain pipe has been raisen up or bent.
Check auto drain.
Check auto drain strainer.
Confluence of piping with another
unit without air dryer.
Install air dryer on the line that does not have it.
Separate two lines not to converge.
Large pressure drop IN / OUT valve on the air dryer
side is not fully opened.
Open IN/OUT valve thoroughly.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMC IDF4E-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMC IDF4E-20 in the language / languages: English as an attachment in your email.

The manual is 0,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info