5 Operation SMA Solar Technology AG
54 SDesign-BA-BEN120432 User Manual
4. To change the displacement power factor cos φ for inverters with reactive power capability,
adjust the cos φ depending on the selected inverter. Here, the displacement power factor cos
φ has an impact on the nominal power ratio of the inverter with reactive power capability. The
minimum possible value for the displacement power factor cos φ is dependent on the selected
inverter with reactive power capability:
•Select [Project data] in the navigation bar.
•In the "Inverter grid connection" area, deactivate the "Specification for displacement power
factor cos φ" field.
•Select [PV plant] in the navigation bar.
In the "Number x inverter name" tab, select the desired sign in the "Displacement power
factor cos φ" field and enter the desired displacement power factor:
5. To adjust the string assignment for the selected inverter, select the "Strings" tab and change the
string assignment as desired.
6. Check the selected combination of PV array and inverter in the area for design evaluation and
adjust if incompatible. Take note of the information in the "Help" area when doing this.
Design part project automatically
1. To only take into account certain inverters in the automatic design, select [Select inverter
categories].
☑The "Inverter categories" window opens.
Activate or deactivate the desired selection fields and select [OK].
The selected filter is used for the inverter suggestions.
2. In the "Inverter" tab, select [Design automatically].
Sunny Design automatically adds suitable inverters to the project tree.
Message is displayed that no design suggestions could be determined.
The selected number of modules or the selected peak power is so low that no design
suggestions could be determined.
Check whether the selected number of modules or peak power is correct.
Check whether the filters for the inverter categories are closed.
Sign Explanation
+ overexcited in the generator reference-arrow system
underexcited in the generator reference-arrow system
Shorten calculation duration for automatic design
Depending on the size and number of the PV arrays and the suitable inverters, the calculation
duration can increase for design suggestions.
To shorten the calculation duration, you can change the specification for the calculation
(see Section 6.11"Change Specification for Calculation of Design
Suggestions",page64) or limit the inverter categories.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA SUNNY DESIGN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA SUNNY DESIGN in the language / languages: English as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SMA SUNNY DESIGN

SMA SUNNY DESIGN User Manual - German - 95 pages

SMA SUNNY DESIGN User Manual - Dutch - 95 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info