Select the parameter Reset operating data and set to Reset operation inhibition.
or
Select the parameter AFCI switched on and set to No and then back to Yes.
This effects resetting of the operation inhibition and the inverter will start feeding in again.
8.6 Updating the Firmware
If no automatic update is set in the communication product (e.g. Cluster Controller) or via the user
interface of the inverter, you have two possibilities to update the inverter firmware:
Updating firmware via the user interface of the inverter.
Updating the firmware via USB flash drive.
Updating firmware via the user interface
Requirement:
An update file with the desired inverter firmware must be available. The update file is, for
example, available for download on the product page of the inverter at www.SMA-Solar.com.
Procedure:
1. Activate the user interface (see Section5.1, page20).
2. Log into the user interface Logging Into the User Interface.
3. Select the menu System Configuration.
4. Select [Settings].
5. In the context menu, select [Updating the firmware].
6. Follow the instructions in the dialog.
Updating the firmware via USB flash drive.
Requirement:
A USB flash drive with maximum 32GB and file system FAT32 must be available.
Procedure:
1. Create an "UPDATE" folder on the USB stick.
2. Save the update file with the desired firmware in the "UPDATE" folder on the USB flash drive.
The update file is, for example, available for download on the product page of the inverter at
www.SMA-Solar.com.
3.
Danger to life due to high voltages
Disconnect the inverter from any voltage sources and open the enclosure lid of the
Connection Unit (see the inverter installation manual).
4. Insert the USB flash drive in the USB port on the communication assembly.
8 Troubleshooting
SMA Solar Technology America LLC
User Manual 63SB30-77-1SP-US-40-BA-en-11
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 7.7-US at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 7.7-US in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info