11 Troubleshooting
SMA Solar Technology AG
Operating manual SBxx-1AV-41-BE-en-10 79
Event number Message, cause and corrective measures
10351
Webconnect error: Unknown SIP registrar |xx|
SIP Registrar not available.
Corrective measures:
Ensure that the network cable at the inverter is correctly connected.
Check the configuration of the router.
10352
Webconnect error: Faulty communication
No connection to SunnyPortal possible.
Corrective measures:
Ensure that the Internet connection is working properly.
Ensure that the Webconnect function is activated.
Ensure that the network cable at the inverter is correctly connected.
10353
Webconnect error: registration of the SIP registry has not responded
SIP Registrar not fully available.
Corrective measures:
Ensure that the network cable at the inverter is correctly connected.
Check the configuration of the router.
10502
Active power limited AC frequency
The inverter has reduced its power due to a too-high power frequency to en-
sure grid stability.
Corrective measures:
If possible, check the power frequency and observe how often
fluctuations occur. If fluctuations occur frequently and this message is
displayed often, contact the grid operator and request approval to
change the operating parameters of the inverter. If the grid operator
gives his approval, discuss any changes to the operating parameters with
Service (see Section14, page94).
10901
Start self-test [xx]
The self-test is running.
10902
Uac RPro [xxx] V
Preliminary result of the self-test
10903
Uac Max [xxx] V
Preliminary result of the self-test
10904
Uac Min [xxx] V
Preliminary result of the self-test
10905
Uac Min Fast [xxx] V
Preliminary result of the self-test
79


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 6.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 6.0 in the language / languages: English as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SMA Sunny Boy 6.0

SMA Sunny Boy 6.0 Installation Guide - German - 104 pages

SMA Sunny Boy 6.0 User Manual - Dutch - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info