Saving the made settings is indicated by an hourglass symbol on the user interface. If the DC
voltage is sufficient, the data is transferred directly to the inverter and accepted. If the DC
voltage is too low (e.g. in the evening), the settings are saved, but they cannot be directly
transferred to or accepted by the inverter. As long as the inverter has not yet received and
accepted the settings, the hourglass symbol will continue to be displayed on the user interface.
The settings will be accepted when there is sufficient DC voltage applied and the inverter
restarts. As soon as the hourglass symbol appears on the user interface, the settings have been
saved. The settings will not be lost. You can log off of the user interface and leave the system.
6.2 Configuring the Country Data Set
As standard, the inverter is meant for connection to a utility grid with a 208V wye connection or a
240V split-phase system, and the associated country data set UL1741/2010/120 is factory-set.
If the default country data set does not correspond with the grid configuration, the country data set
can be adapted to the connected grid configuration.
The basic procedure for changing operating parameters is explained in another section (see
Section6.1 "Changing Operating Parameters", page30).
Grid configuration Country data set
208Vdelta connection UL1741/2010/208
208 V wye connection UL1741/2010/120
240 V delta connection UL1741/2010/240
240V split-phase system UL1741/2010/120
Procedure:
Select the parameter Set country standard and set the required country data set.
6.3 Deactivating the Arc-Fault Circuit Interrupter (AFCI)
The basic procedure for changing operating parameters is explained in another section (see
Section6.1 "Changing Operating Parameters", page30).
Procedure:
Select the parameter AFCI switched on or AfciIsOn and set to No.
6 Configuration of the Inverter
SMA Solar Technology America LLC
User Manual 31SB30-77-1SP-US-40-BA-en-11
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 6.0-US at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 6.0-US in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info