6 Configuration of the Inverter
6.1 Changing Operating Parameters
The operating parameters of the inverter are set to certain values by default. You can change the
operating parameters to optimize the performance of the inverter.
This section describes the basic procedure for changing operating parameters. Always change
operating parameters as described in this section. Some function-sensitive parameters can only be
viewed by qualified persons and can only be changed by qualified persons by entering the
personal SMA Grid Guard code.
No configuration via SunnyExplorer
SunnyExplorer does not support the configuration of inverters with their own user interface.
The inverter can be detected via SunnyExplorer, however it is expressly not recommended to
use SunnyExplorer to configure this inverter. SMA does not accept liability for missing or
incorrect data and possibly resulting yield losses.
Use the user interface for the configuration of the inverter.
Requirements:
The changes to the grid-relevant parameters must be approved by the grid operator.
When changing grid-relevant parameters, the SMAGridGuardcode must be available (see
"Application for SMAGridGuard Code" at www.SMA-Solar.com).
Procedure:
1. Activate the user interface (see Section5.1, page20).
2. Log into the user interface (see Section5.2, page23).
3. Call up the menu Device Parameters.
4. Select [Edit parameters].
5. Log in using the SMA Grid Guard code to change those parameters designated by a lock
(only for installers):
Select the menu User Settings (see Section5.3, page25).
In the subsequent context menu, select [SMA GridGuard login].
Enter the SMA Grid Guard code and select [Login].
6. Expand the parameter group that contains the parameter which is to be configured.
7. Change the desired parameters.
8. Select [Save all] to save the changes.
The inverter parameters are set.
6 Configuration of the Inverter
SMA Solar Technology America LLC
User ManualSB30-77-1SP-US-40-BA-en-1130
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 5.0-US at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 5.0-US in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info