E Display
The display shows the current operating data and events or errors (see Sec-
tion9.2 "Display Overview", page41).
F ElectronicSolarSwitch (ESS)*
The ESS and the DC connectors together form a DC load-break switch. When
plugged in, the ESS forms a conductive path between the PV array and the in-
verter. Removing the ESS interrupts the DC electric circuit and removing all DC
connectors disconnects the PV array completely from the inverter.
G Lower enclosure lid
* Optional
Symbols on the inverter, the type label and the ESS
Symbol Explanation
Inverter
Together with the green LED, this symbol indicates the operating state of
the inverter.
Observe the documentation
Together with the red LED, this symbol indicates an error (for trou-
bleshooting, see the service manual at www.SMA-Solar.com).
BLUETOOTH
Together with the blue LED, the symbol indicates active communication
via BLUETOOTH.
Danger
This symbol indicates that the inverter must be additionally grounded if
additional grounding or equipotential bonding is required at the installa-
tion site (see Section6.3.3, page27).
QRCode
Links to additional information on the inverter can be found at
www.SMA-Solar.com.
Operating the inverter without the lower enclosure lid is prohibited. Al-
ways operate the inverter with the lower enclosure lid.
4 Product Description
SMA Solar Technology AG
Operating Manual 13SB30-50TL-21-BE-en-11
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 3600TL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 3600TL in the language / languages: English as an attachment in your email.

The manual is 2,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SMA Sunny Boy 3600TL

SMA Sunny Boy 3600TL User Manual - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info