10 Troubleshooting SMA Solar Technology AG
54 SB13_21TL-IA-en-65 Installation Manual
10.5 Red LED Permanently On
If the red LED is permanently on during operation, there is an earth fault present in the PV array or at
least one of the varistors for overvoltage protection is defective.
Procedure:
Check the PV array for earth faults (see Section10.5.1 "Checking the PV Array for Earth Faults",
page54).
If the red LED does not go out, check the function of the varistors (see Section10.5.2 "Checking
the Function of the Varistors", page55).
10.5.1 Checking the PV Array for Earth Faults
If the red LED is on and the inverter displays the message Riso, there is an earth fault in the PV array.
The electrical insulation between the PV plant and earth is defective or insufficient.
Proceed as follows to check each string in the PV plant for earth faults.
1. Disconnect the inverter from all voltage sources (see Section 8).
2. Measure the voltages:
Measure the voltages between the positive pole and the earth potential (PE).
Measure the voltages between the negative pole and the earth potential (PE).
Measure the voltages between the positive and negative poles.
If the following results are returned simultaneously, there is an earth fault in the PV plant.
All measured voltages are stable.
The sum of the two voltages against earth potential is approximately equal to the voltage
between the positive and negative poles.
Determine the location of the earth fault via the ratio of the two measured voltages, and
eliminate the earth fault.
If there is no earth fault present and the message is still displayed, contact the SMA Service Line.
Danger to life due to electric shock
In the event of an earth fault, high voltages can be present.
Only touch the cables of the PV array by their insulation.
Do not touch any parts of the sub-structure or frame of the PV array.
Do not connect PV strings with earth faults to the inverter.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 1600TL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 1600TL in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SMA Sunny Boy 1600TL

SMA Sunny Boy 1600TL User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info