12 Technical Data SMA Solar Technology AG
62 SB13_21TL-IA-en-65 Installation Manual
Protective Devices
Climatic Conditions in Accordance with IEC 60721-3-4, Installation Type C,
Class 4K4H
Climatic Conditions in Accordance with IEC 60721-3-4, Transport Type E,
Class 2K3
Degree of protection according to IEC 60529 IP65
Protection class according to IEC 62103 I
Grid configurations TN-C system, TN-S system, TN-C-S system,
TT system, when V
N_PE
> 30 V, IT system,
Delta-IT system, Split Phase
Licences (as per 04/2013) CE, VDE0126-1-1, G83/1-1, RD 661/2007,
PPC, AS 4777, EN 50438, C10/11, PPDS,
UTE C15-712-1, VDE-AR-N 4105, CEI 0-21,
RD1699*, NRS 097-2-1**, DIN EN 62109-1,
IEC 62109-2***
* To find out about restrictions in certain regions, contact the SMA Service Line.
** This standard stipulates that a special label be attached to the AC distribution to draw attention to the AC-side
disconnection of the inverter in the event of grid failure (for more details, see NRS 97-1-2, Sec. 4.2.7.1 and 4.2.7.2)
*** In order to meet the requirements of this standard, use of the fault indication relay must be activated in the inverter or there
must be a link to Sunny Portal with the fault alert via e-mail activated.
DC reverse-polarity protection short-circuit diode
Input-side disconnection device*
*optional
Electronic Solar Switch
DC overvoltage protection thermally monitored varistors
AC short-circuit protection current control
Grid monitoring SMA Grid Guard 2.1
Maximum permissible fuse protection 16 A
Earth fault monitoring Insulation monitoring: R
iso
> 1 MΩ
All-pole sensitive residual-current monitoring unit installed
Extended temperature range − 25°C to +60°C
Extended humidity range 0% to 100%
Extended air pressure range 79.5 kPa to 106 kPa
Temperature range − 25°C to +70°C
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SMA Sunny Boy 1300TL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SMA Sunny Boy 1300TL in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SMA Sunny Boy 1300TL

SMA Sunny Boy 1300TL User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info