544778
3
Zoom out
Zoom in
Previous page
1/14
Next page
GB
Thank you for purchasing this SkyTronic inverter. Read this manual carefully and keep it for future reference.
Warnings
- Read the manual prior to using the unit.
- Keep the manual for future reference.
- Keep the packaging for safer transport in its original packaging
- Install the unit in such a way that sufficient cooling is ensured.
- The unit contains voltage carrying parts. DO NOT open the unit.
- When you unplug the unit from the mains always pull the plug, never the lead.
- Never plug or unplug the unit with wet hands.
- If the plug and/or mains lead are damaged, they need to be repaired by a qualified technician.
- If the unit is damaged to an extent that you can see internal parts, do not plug the unit into a mains
outlet.
- Repairs have to be carried out by a qualified technician.
- Do no place the unit near heat sources.
- When the unit operates, NEVER touch the battery clamps, this may result in electric shock.
- Do not clean the unit with solvents or detergents. Only use a dry cloth for cleaning.
- Make sure that no small objects or liquids can enter the housing.
General Features
This range of inverters from SkyTronic transforms a 12 VDC battery voltage into a 230 VAC mains voltage.
Thus enabling you to use your domestic equipment everywhere you want to use it. It can be used on boats,
caravans, campers, cars etc.
Important!
Under full load, high current is flowing through the battery cables. Therefore it is recommended to use only
the supplied cables and no extension cables in order to avoid unacceptable voltage losses. If necessary, use
an extension cord in the 230V circuit to the connected unit. To comply with the legal standards, the inverter
may only be used with the supplied low voltage cables. Do NOT extend them.
The connected battery must be in good condition and fully charged. After some time, it may be necessary to
start the car or boat in order to recharge the battery. At that moment, the inverter must be switched OFF
beforehand in order to avoid damage due to excessive battery voltage.
GENERAL SAFETY
1. Always operate the inverter from the correct power source, 12V or 24V battery (As applicable).
2. When connecting the cables from the battery to the inverter observe the correct polarity, RED is positive
(+) and BLACK is negative (-). REVERSING the polarity will damage the inverter and is not covered by
the warranty.
3. Ensure the DC input connections are secure, because a loose contact can result in excessive voltage
drop and can cause overheated wires and melted insulation.
4. Locate the inverter and power source (battery) away from any inflammables to avoid any possible fire or
explosion. NOTE. It is normal to experience sparks when connecting the positive terminal of the inverter
from the battery. This is due to the current flow charging the capacitors in the inverter.
5. Where applicable, always ground the inverter before operation to avoid possible shock.
6. Check that the power consumption of the appliance to be operated is compatible with the output capacity
of the inverter. Thus, you can’t power a 450W drill machine with a 300W inverter.
7. The battery must be of adequate capacity (ampere-hour) to run the inverter at the required power. The
maximum current ratings for the various inverter models are:
12V-300W = 33A
The capacity of a battery is stated in Ah (Amps/hour) and is noted on the battery. This capacity is
applicable over a period of 20 hours. Example: A battery with a capacity of 48 Ah can deliver a current of
2.4 Amps during 20 hours or a current of (a bit less than) 4.8 Ah during 10 hours. At a higher current, the
capacity is always a bit lowered.
8. Insert an in-line fuse with the proper rating into the cable leading to the battery.
9. Disconnect the inverter when not in use.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Skytronic 651.536 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Skytronic 651.536 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info