b) Do not use the power tool if the switch does not turn
it on and off. Any power tool that cannot be controlled
with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source and/or
the battery pack from the power tool before making
any adjustments, changing accessories, or storing
power tools. Such preventive safety measures reduce
the risk of starting the power tool accidentally.
d) Store idle power tools out of the reach of children
and do not allow persons unfamiliar with the power
tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained
users.
e) Maintain power tools. Check for misalignment or
binding of moving parts, breakage of parts and any
other condition that may affect the power tool’s
operation. If damaged, have the power tool repaired
before use. Many accidents are caused by poorly
maintained power tools.
f) Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc.,
in accordance with these instructions, taking into
account the working conditions and the work to be
performed. Use of the power tool for operations
different from those intended could result in a
hazardous situation.
5) SERVICE
a) Have your power tool serviced by a qualified repair
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.
SAFETY INSTRUCTIONS FOR MIXERS
Always check that the supply voltage is the same as the
voltage indicated on the nameplate of the tool (tools
with a rating of 230V or 240V can also be connected to
a 220V supply)
Never use the tool without the protection frame
Never use the tool in or near an explosive atmosphere
Never mix combustible substances
Never reach with your hand or any other object into the
mixing container during mixing
Wear protective gloves 4, a dust mask 5, close-fi tting
clothes and sturdy shoes
The noise level when working can exceed 85 dB(A);
wear ear protection 6
SKIL can assure fl awless functioning of the tool only
when original accessories are used
Always disconnect plug from power source before
making any adjustment or changing any accessory
WHEN CONNECTING NEW 3-PIN PLUG (U.K. ONLY):
Do not connect the blue (= neutral) or brown (= live) wire
in the cord of this tool to the earth terminal of the plug
If for any reason the old plug is cut off the cord of this
tool, it must be disposed of safely and not left
unattended
USE
• On/off 7
Switch locking for continuous use 8
! be aware of the forces that occur as a result of
jamming; hold the tool firmly with both hands and
take a secure stance
Speed control for smooth starting 9
• Maximum speed control 0
With wheel C the maximum speed can be adjusted from
low to high
- switch on the tool
- lock the switch
- turn wheel C to select maximum speed
• Protection frame !
- for protecting the tool
- for guiding the tool
- for putting aside the tool in a simple way
- mount protection frame D before using the tool for
the fi rst time
! never use the tool without the protection frame
• Operating the tool
! ensure that the tool is switched off
- mount mixing paddle F onto spindle E as illustrated @
- connect plug to power source
- ensure the mixing container is securely positioned on
the fl oor
- dip the mixing paddle into the blending substance
before switching on the tool, and then gradually
increase the blending speed by putting more
pressure on trigger A 2 (so that the substance will
not splash around and the tool will not be
overloaded)
! switch the tool off only when the mixing paddle is
in the mixing container
Holding and guiding the tool #
! while working, always hold the tool at the grey-
coloured grip area(s)
! always hold the tool firmly with both hands
MAINTENANCE / SERVICE
Always keep tool and cord clean (especially the
ventilation slots)
- always clean the mixer and functional parts after your
mixing work
- clean the tool with a dry, soft cloth (do not use
cleaning agents or solvents)
- clean ventilation slots G 2 regularly with a brush or
compressed air
! disconnect the plug before cleaning
If the tool should fail despite the care taken in
manufacturing and testing procedures, repair should be
carried out by an after-sales service centre for SKIL
power tools
- send the tool undismantled together with proof of
purchase to your dealer or the nearest SKIL service
station (addresses as well as the service diagram of
the tool are listed on www.skileurope.com)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Skil 1609 AA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Skil 1609 AA in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info