Emergency hoisting and lowering
In case of a failure or an emergency in the normal hoist/lower
operation controlled from the Sonar Operating Panel, the
transducer may be hoisted and lowered from the Sonar Room.
Local control switch S302
If the 3-phase voltage for the hoist/lower motor and the +24 Vdc
stand-by voltage from the Transceiver Unit are available, the
transducer can be hoisted or lowered by means of switch S302
in the Motor Control Unit. The motor will automatically stop
when the transducer shaft reaches the upper or lower limit
switch.
Remember to set the switch back to Remote position when
finished.
Hoist/lower contactors K301 and K302
If the 3-phase voltage for the hoist/lower motor is available, the
transducer can be hoisted and lowered by operating the hoist
(K301)andlower(K302) contactors in the Motor Control Unit
by activating the small switch handle on the front of the
contactor.
Warning The switches must be released before the
transducer shaft reaches upper or lower position,
as this operation overrides the two limit switches.
Manual hoist and lower operation
If the 3-phase voltage is not available, the transducer must be
hoisted and lowered by means of the hand crank. Observe the
following procedure.
1. Locate the motor overload switch S301 in the Motor
Control Unit, and press the red button marked 0.
2. Locate the hand crank in the Motor Control Unit.
3. Remove the plastic plug on the top cover of the Hull Unit,
and mount the hand crank onto the stub shaft through the
hole in the top cover.
4. Locate the brake release screw on the motor. Use an Allen
key to tighten up the screw until the motor brake is
released. Approximately 2 - 3 turns clockwise are
required.
5. Use the hand crank to hoist and lower the transducer.
6. When finished, loosen the brake release screw to engage
the motor brake. Check with the hand crank to ensure that
the motor brake is engaged.
176


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad SP90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad SP90 in the language / languages: English as an attachment in your email.

The manual is 2,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Simrad SP90

Simrad SP90 User Manual - Spanish - 186 pages

Simrad SP90 User Manual - Norwegian - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info