23336
281
Zoom out
Zoom in
Previous page
1/322
Next page
Sensor test procedures
269
850-165186 / Rev.B
Spread & Remote sensors test procedure
Tools and equipment required
Multimeter
A small piece of wire
PI Service Hydrophone (Order no. 314-204480)
PI System
Initial check and setup identification
On both sensor types, keep the area between the negative
charging lug (A) and the water detector (B) c lean to reduce the
risk of activating the sensor. If necessary, apply silicon grease to
disrupt conductive paths.
1 On both sensors, use a multimeter to check the voltage
between the negative charging lug (A) and the water
detector (B). Make sur e the sensor is charged:
- Fully discharged: Voltage less than 11.5 Vdc
- Fully charged: Voltage greater than 13.5 Vdc
- Approximately 50% capacity left: 12.8 Vdc
2 With a small piece of wire, complete the circuit between
the sensor’s sea water detector (B) and negative charging
lug (A).
- The sensor will respond by flashing its individual LED
identification codes.
(1) = One long flash: It has a duration of
approximately 1 second.
(2) = One start flash: This signals that the first digit of
the channel number is next.
(3) = None, one, two or three short flashes: The
number of short flashes signifies the first digit of the
configured channel number.
281


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad PI54 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad PI54 in the language / languages: English as an attachment in your email.

The manual is 10,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Simrad PI54

Simrad PI54 User Manual - Norwegian - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info