23336
241
Zoom out
Zoom in
Previous page
1/322
Next page
PI Configurator
229
850-165186 / Rev.B
About sensor configuration
All sensors are provided from the factory with pre-defined
communication channels and update rates.
Sensor Com.channel Update rate
PI Bottom Contact 6 Normal
PI Catch 4 Normal
PI Depth (300 m) 16 Fast
PI Depth (600 m) 12 Fast
PI Depth (1000 m) 10 Fast
PI Height 14 Fast
PI Spread 2 Fast
PI Twin Spread 2 and 7 Fast
PI Temperature 8 Fast
Factory default communication channels and update rates
Changing a transmission channel
It may be required to change one or more transmission channels,
and there may be many reasons for this.
You have more than one of each sensor. For example, if you
have three temperature sensors, they MUST communicate on
three different channels.
Other vessels near your use the same PI Configurator system
(or a similar), and they have one or more of their sensors set
up to the same communication channels as you have. This
will create interference, as you will “read” each others
sensors.
If your sensors are set up to use communication channels too
close to each other (for example, you have chosen channels
4, 5 and 6), this will limit the vessel’s speed. The reason for
this is the doppler effect. If the speed is too high, the doppler
will cause the transmission frequencies to change so much
that they overlap, and this will create interference. The PI
Configurator will provide a warning if this is about to
happen! You must then either change to other communication
channels further apart, or reduce the maximum shooting
speed.
If you operate at the maximum range of the sensors, you may
be able to increase this range slightly if you use lower
communication channels. This is because the l ower
communication channels user lower transmission
frequencies.
241


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad PI54 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad PI54 in the language / languages: English as an attachment in your email.

The manual is 10,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Simrad PI54

Simrad PI54 User Manual - Norwegian - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info