572713
34
Zoom out
Zoom in
Previous page
1/66
Next page
34
|
NMEA2000 / SimNet | NSS Installation Manual
Planning and installing a SimNet backbone
Plan the SimNet backbone carefully
Note: For part numbers refer to ‘SimNet Accessories’ page “Simnet Cables on page 60
The SimNet backbone needs to run between the locations of all SimNet products you want to
install, and be less than a 5.5 m (18 ft) cable run from a SimNet device.
Choose from the following components to make up your SimNet backbone:
SimNet cables: 0.3 m (1 ft), 2 m (6,6 ft), 5 m (16.6 ft), and 10 m (33 ft) cables
SimNet power cables with or without termination
SimNet in-line joiner with or without termination
T-Joiner. Use at locations where you want to connect a single SimNet device or join lengths of
SimNet cable
7 way joiner. Use to connect up to 5 devices at one location
Wind transducer. If using a wind sensor, plan to connect this to one end of the backbone as
this has a terminator built in
Power the SimNet network
A SimNet network requires its own 12 V DC power supply protected by a 5 amp fuse or
breaker. For 24 V use a DC-DC converter
Connect power at any location in the backbone for smaller systems using a SimNet power
cable with termination (red cap).
For larger systems introduce power at central point in the backbone to “balance the voltage
drop of the network. Use SimNet cable without termination (yellow cap, part # 24005910). See
diagram on page 36.
If joining to an existing NMEA2000 network or similar CAN bus network that has its own
power supply, do not connect to another power supply.
Do not connect the SimNet power cable to the same terminals as the start batteries, Autopi-
lot Computer, Radar, thruster or other high current products
The drawing below shows a small SimNet network. Power is introduced at one end using a
SimNet power cable with termination ending with a second terminator.
12 V DC
T
T
Mico-C to SimNet
SimNet power
SimNet terminator
-
+
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad NSS Chartplotter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad NSS Chartplotter in the language / languages: English as an attachment in your email.

The manual is 18,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Simrad NSS Chartplotter

Simrad NSS Chartplotter User Manual - English - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info