System overview
The Simrad ME70 offers
quantitative data and high operational
exibility. It provides a congurable
wide fan of stabilized and calibrated
beams for biomass estimation, sh
school characterization. and behaviour
studies.
All beams can be congured as
split beams providing data for single
target analysis, such as target strength
measurements and target tracking.
The sector of calibrated narrow
split beams with low sidelobe levels
and short pulse lengths allow for
accurate biomass estimation very
close to the bottom. The ability to
adjust the athwartship centre angle of
the fan enables you to use the system
for studying sh close to ridges and
slopes. The design also permits you
to use all the beams over the full
frequency range pointing in one
direction for frequency comparison.
Not just an ordinary
multibeam sounder
Within the bandwidth of the
transducer, the limits for beam
steering, and the minimum achievable
beam opening, you can select the
directions, frequencies, and opening
angles for the beams in the Simrad
ME70.
You will be able to congure the
system to t your requirements, and
the system will provide you with a
real-time display for quality control of
the current data acquisition.
The system conguration can be
tailored to any user requirements,
allowing for choice of beamwidths as
well as transmission modes.
Low sidelobe levels and
beam interleakage
Low sidelobes are important for
two reasons. The obvious one is to
avoid that strong targets in side lobes
are mistaken for weak targets in the
main lobe. Secondly, you do not wish
to see strong bottom echoes from the
sidelobes. Even the vertical receiver
beam may benet from low sidelobes
in case of a sloping bottom.
Very low two-way sidelobe levels
are obtained by using two-way side
lobe suppression. Very low beam
interleakage is obtained by using
Frequency Rotated Directional
Transmission (FRDT) where the
frequency band is distributed over all
the beams.
Since each beam has its own
frequency and the fan width is
congurable, the design also allows
you to use all the beams over the
full frequency range pointing in one
direction for frequency analysis of
targets.
Key points
The Simrad ME70 operates in
the 70 to 120 kHz frequency
range.
The Simrad ME70 provides
a congurable acoustic fan
containing 3 to 45 stabilized
beams.
All beams can be congured as
split beams.
Calibration software included.
Minimum beam opening is
2° depending on operational
frequency and steering.
140° maximum total swath
width.
The athwartship centre angle
of the fan can be adjusted from
+45° to -45°.
Minimum acquisition depth
is less than 1 m below the
transducer depending on beam
mode conguration.
Sidelobe levels and beam
interleakage are adjustable
from -35 to -70 dB depending
on beamwidth and frequency
conguration.
System description
(CD10104G)
Calibration
A calibration utility is
implemented as a special built-in
function in the Simrad ME70 system.
Each beam conguration of interest
can be calibrated using a reference
target located under the ship.
Individual gain parameters for
each beam are adjusted to provide
calibrated target strength and volume
backscattering strength measurements.
Splitbeam conguration
All beams can be congured
as split beams. In addition, two
adjustable reference split beams are
available. These allow you to compare
ME70 data with data from other split
beam systems, for example the EK60.
The reference beams can for example
have 7x7 degrees opening angles, and
operate on 70 and 120 kHz.
The data from the individual split
beams are presented in the same way
as on other Simrad scientic sounders.
Data output
It is possible to set up continuous
output of all beam data. This can be
used for echo integration and 3D
visualisation. The output data for each
beam include for example:
non-TVG compensated sample
power and sample angle
20 log R compensated sample Sv
40 log R compensated sample TS
40 log R compensated single target
detections
Detected depth
It is also possible to output the
element data for post processing and
analysis purposes.
Remote operation
Remote systems, such as data
loggers and external post-processing
systems, can subscribe to data and
parameters from the Simrad ME70.
The parameters can also be queried
and dened by the remote system. In
this way the communication between
the ME70 and the remote system can
become an efcient, congurable,
two-way communication.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad ME70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad ME70 in the language / languages: English as an attachment in your email.

The manual is 4,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info