23322
98
Zoom out
Zoom in
Previous page
1/108
Next page
901-10037001/1.1 FS 20/25 Operators Manual
Page 5.26 Maintenance and Troubleshootin
g
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
If the impedance between the cable’s two conductors is too low, then
possible problems are bad splices, water in cable, moisture in slip rings (if
connected during test), or damaged cable. If the impedance between the
cable’s conductors and the vessel’s hull is too low, then possible causes are
damaged outer jacket on cable, bad splice, or bad slip rings (if connected
during test).
Closed Loop Resistance
As previously mentioned, the closed loop resistance must be less than 100 ohms for
proper operation of the FS system. This test should be done with the FS system
disconnected, but with the winch slip rings included.
To do the test, the conductors at one end of cable should be jumpered together
(shorted). An ohmmeter is then used at the other end of cable to measure the
resistance between the conductors.
Voltage and Current at Trawl Unit
Further checks of cable losses can be performed by measuring both the voltage and
current at the trawl unit. This measurement requires the trawl unit electronics to be
connected and the FS system powered up. This test is done where the trawl cable
pigtail plugs into the sonar head. Jumpers will be required to breakout the signals
for connection to a handheld multi-meter.
Caution!
There are DC voltages on the trawl cable that are capable of
delivering a lethal electric shock!
The minimum voltage at the trawl unit is 55 Vdc and the current should be
approximately 250 mA with sonar head only connected and 325 mA with both sonar
head and sensor module (current readings will vary depending on operation mode -
i.e., scan speed and range, etc.). This test is recommended more for a service
representative than ship's personnel in the field.
Test for Water In Cable
When a trawl cable is damaged or there is a poor splice, salt water can get into the
cable. As a result, the cable may act as a battery, producing a small dc voltage
across the conductors of the cable. This is detrimental to the operation of the FS
system and all affected cable should be removed.
To test for this, the trawl cable should be disconnected from the FS system and a
voltage meter connected to the trawl unit end of the cable. If water is present, then
98


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad FS25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad FS25 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info