Cable Gain Calculations
To illustrate how you can evaluate these “Cable Gain” numbers, let’s assume that
your system gave the above as Cable Gain numbers for the FS20 Vertical Head
(LF1) on an 8’ service test cable…………Cable Gain 6,44
Number A = 6
Number B = 44
A general rule of thumb formula for establishing real time cable attenuation (for
which the system is compensating) is as follows:
Cable Attenuation (dB) = 20 log [ (Number A x Number B) / 36]
In the above example, the cable gain numbers would produce the following result:
Cable Attenuation (dB) = 20 log [(6 x 44)/36]
= 20 log [7.33]
= 17.3 dB
The key thing to note here is that the calculated attenuation is < 40 dB (which is one
of the system specifications). If over a period of time, you notice that the cable gain
numbers are getting larger, the calculated attenuation will start to approach 40 dB.
Once it goes beyond 40 dB, the system will not be able to compensate and you will
start getting telemetry errors or outright system failures. There is a direct relationship
between a degrading 3
rd
wire and the cable gain.
By periodically checking the cable gain compensation numbers and comparing it to a
previously recorded value, the condition of the trawl cable can be monitored.
5.4.4 System Error Messages
In the normal operation of the FS Trawl Monitoring system, commands are sent from
the processor unit down the trawl cable, to the trawl unit electronics and
acknowledgments are then sent back up to the processor unit.
Telemetry errors can result from noise induced on the trawl cable due to
interference, or problems with the trawl cable or trawl unit electronics. Though a few
telemetry errors are quite common and acceptable, an excessive number of errors
will adversely affect the sonar operation and may indicate a problem that will
eventually cause a system failure.
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad FS25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad FS25 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info