901-10037001/1.1 FS 20/25 Operators Manual
Page 4.32 FS 20/25 Installation, System Set-Up and Test
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
4.4.17 Final System Test
After preparing the trawl cable and before final trawl unit assembly, a system test
should be conducted to insure correct operation of FS 20/25 Trawl Monitoring
System over the trawl cable.
As before, the start up procedures should be followed to power up the system. Once
the FS 20/25 has been turned on, the power supply voltage and current meters should
be examined. Expected values are 0.2 – 0.5 (output voltage selection switch should
be set to FS 20) or FS 25 if you have an FS 925 sonar connected. If the voltage and
current values differ significantly from these values, it indicates a problem with the
trawl cable or its connections.
If there are any errors during the calibration, a status report page will appear
containing the results that the control unit obtained from tests performed. Again, any
errors will be due to the trawl cable or its connections. Check the connections again
and insure that the signal polarity at the trawl unit is correct. A DC voltmeter can be
used to check that the positive voltage is on the small pin of the pigtail when the
FS 20/25 PWR/TTM unit is powered up.
If all is okay, then the sonar image display will appear and the sonar head will begin
scanning.
4.4.18 Completing Trawl Unit Assembly
The final step in the installation is to complete the trawl unit assembly and mount it
to the headrope as shown on drawings in Chapter 7.
First, the plastic cable strain relief supplied with the trawl unit must be bolted to the
trawl cable. The location should be at or very near the pigtail splice, but NOT on the
pigtail itself. You must slide the rubber hose on the trawl cable, if used, down so
that approximately 3-4 cm (1-2") of the hose is clamped inside the strain relief.
Next, the trawl cable is connected to the sonar head. Liberal amounts of Dow Corning
#55 grease are applied to the connector surfaces before mating so that a water tight
seal is obtained. The locking sleeve is then hand-tightened.
Note!
Dow Corning #55 grease must be applied to all mating surfaces of
underwater connectors to insure proper sealing. Sufficient grease
should be applied so that excess squeezes out with any air when the
connectors are mated. RTV or any other sealant must NOT be used,
and when tightening the locking sleeves do NOT use a wrench or
pliers! See chapter 5, "Troubleshooting and Maintenance", for proper
connector maintenance.
69


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad FS25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad FS25 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info